0 hardware and software operating requirements, 0 specifications, 1 unit dimensions – Keri Systems LC-508 Proximity Elevator Control User Manual
Page 2: 2 operating temperature and humidity range, 3 power requirements, Proximity elevator control panel
Proximity Elevator Control Panel
2305 Bering Drive
01941-001 Rev. B
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]
Page 2 of 22
Quick S
tart Guide
LC-502P/LC-508P
2.0
Hardware and Software Operating Requirements
All standard hardware and software requirements for Doors software apply (refer to the Doors
Users Guide – P/N 01914-100). To support elevator control, the following additional software and
firmware requirements must be met.
•
The Doors software must be at revision 4.10 or greater.
•
The controller firmware must be at revision 8.4.12 or greater.
3.0
Specifications
3.1
Unit Dimensions
•
LC-500P Controller PCB
-
7.00 inches high by 6.00 inches wide by 1.25 inches deep, including wiring connectors
-
(17.78 cm by 15.24 cm by 3.18 cm)
•
LC-500P Controller PCB with an LCD-1 Alpha/Numeric Display
-
7.00 inches high by 6.00 inches wide by 1.5 inches deep, including wiring connectors
-
(17.78 cm by 15.24 cm by 3.81 cm)
•
LC-500P Controller PCB with an SB-500 Satellite Board (with or without an LCD-1 Alpha/
Numeric Display
-
7.00 inches high by 6.00 inches wide by 2.00 inches deep, including wiring connectors
-
(17.78 cm by 15.24 cm by 5.08 cm)
•
LC-502P Enclosure
-
13.00 inches high by 9.00 inches wide by 4.00 inches deep
-
(33.02 cm by 22.86 cm by 10.16 cm)
•
LC-508P Enclosure
-
18.50 inches high by 15.25 inches wide by 4.00 inches deep
-
(47.00 cm by 38.75 cm by 10.16 cm)
3.2
Operating Temperature and Humidity Range
•
0°F to 140°F (-18°C to 60°C)
•
0% to 90% Relative Humidity, non-condensing
3.3
Power Requirements
•
12 VDC @ 750 mA for the LC-502P panel
•
12 VDC @ 3 A for the LC-508P panel