3.1
PXL-250 Connections
The "A" reader connects to TB5, pins 1 through 6 (TB5 has a seventh pin, but no connection is
made to that pin). The "B" reader connects to TB6, pins 1 through 6 (TB6 has a seventh pin, but no
connection is made to that pin).
Connecting to the PXL-250 – TB5 or TB6
Figure 2: PXL-250 Connections
Pin #
Function
Wire Color
1
Reader Antenna
Blue
2
Beeper
Green
3
Reader Power
Red
4
Reader Ground
Black
4
Shield
Silver
5
Green LED
Brown
6
Red LED
White
7
no connection
–