beautypg.com

Firmware upgrade via ftp – Clipcomm CWP-100 User Manual

Page 38

background image

37


10.2. Firmware Upgrade via FTP

Upgrading the firmware via FTP is the fastest way. But this process is available only when the network is in

normal state and connected properly.

The following example shows how a command line FTP client is used to upload new firmware (“CWP-

100.fls”) to the CWP-100 when its IP address is 192.168.0.36. Enter “admin” as the user name and type in

the password that is set on the VoIP configuration web page. The default password is “0000.”

C:\> ftp 192.168.0.36

Connected to 192.168.0.36.

220 Precise/RTCS FTP Ready

User (192.168.0.36:(none)): admin

331 Password required for admin

Password: 비밀번호(4자리숫자) 입력

230 Logged in

ftp> bin

200 Type OK

ftp> put CWP-100.fls flash

200 Port command okay

150 Opening data connection for STOR (192.168.0.14,1161)

226 File received OK – 1053136 bytes in 10.640 sec

ftp: 1053136 bytes sent in 10.55Seconds 99.82Kbytes/sec.

The system will reboot automatically when upgrading the firmware via FTP is completed.

CAUTION: Do not interfere until upgrading the firmware is completed. Upgrading procedure

normally takes few minutes by using FTP. The system will restart automatically when the process
is completed.

We recommend that you reset the system by factory value after the firmware upgrade. Follow the
steps as”4. Extra Setting” ”7. Firmware” ”1. Load Default” to reset the system.