beautypg.com

Measure and establish location of cage, Establish the motor reference point – Jaypro Sports BBC-UBKIT User Manual

Page 8

background image

© 2010 Jaypro Sports Equipment BBC-700B-M 02-08-2012

8 of 24


PACKAGE 7

BBC-700M

(1) BBC-700M

12' X 10' X 70' TUNNEL #252 3/4" SQ NETTING


CAGE SUPPORT KITS (Contains Attachment Kit and Support Structure)

BBC-UBKIT

(Direct Attached)

Purchased Separately

(9)

SR5239-36

1 5/8 x 1 5/8 x 36 in SINGLE STRUT CHANNEL

(18)

HM6157 SINGLE

STRUT

BEAM

CLAMP

ASSEMBLY

BBC-UP5KIT

(Spanning Parallel 5 ft. or less)

Purchased Separately

(9)

SR5239-96

1 5/8 x 1 5/8 x 96 in SINGLE STRUT CHANNEL

(36)

HM6157 SINGLE

STRUT

BEAM

CLAMP

ASSEMBLY

BBC-KIT58

(Spanning Parallel 5 ft. to 8 ft)

Purchased Separately

(9)

SR5243-120

1 5/8 x 3 1/4 x 120 in DOUBLE STRUT CHANNEL

(36)

HM6159 DOUBLE

STRUT

BEAM

CLAMPS


BBC-PERPKIT

(Spanning Perpendicular)

Purchased Separately

(2)

SR5239-24

1 5/8 x 1 5/8 x 24 SINGLE STRUT CHANNEL

(8)

SR5243-240

1 5/8 x 3 1/4 x 240 in DOUBLE STRUT CHANNEL

(6)

HM6222

4 HOLE PLATE

(32)

HM6159

BEAM

CLAMPS

(24)

HS5133

1/2 -13 x 1 1/4 in HEX HEAD CAP SCREW

(4)

HW2050

3/8

FLAT

WASHER

(4)

HS 286

3/8-16 x 1 in HEX HEAD CAP SCREW

(4)

HM6158

3/8-16

STRUT

NUT

(24)

HM6134

1/2

-13

STRUT

NUT


BBC-RIGKIT

(Peaked or Rigid Frame Buildings) Purchased Separately

(See BBC-RIGKIT support drawing package for detailed parts lists)

MEASURE AND ESTABLISH LOCATION OF CAGE.

1. The cage is 12’ Wide by 70’ long once assembled.
2. There should be a clear area around the perimeter of the cage that is 3’ minimum.
3. The motor of the cage should be located outside the frame to allow for service to the

motor in either the retracted or down position.

ESTABLISH THE MOTOR REFERENCE POINT.

1. The assembly of the cage and drive system is based on the establishment of a motor

reference point.

2. The motor reference point is on the center line of the 12’ side of the cage on either end

of the cage frame.

3. The reference point must be transferred to the ceiling structure of the building to

establish the attachment points for the motor and drive pipe carriers.

4. A plumb laser is the preferred method for achieving this location.

This manual is related to the following products: