MAINTENANCE (continued)

MAINTENANCE

1. Switch off the unit, unplug the power cord from the electrical socket.

2. Turn both plunger valve handles fully clockwise until they stop. This closes the

valve, prevents the water from flowing out of the pool.

3. Disconnect the hose with nut (8) from the Saltwater System, and assemble the

cell cover

(30) at the side of the cell.

4. In a counter-clockwise motion, unscrew the collar of the copper electrode (14)

and remove it from the electrolytic cell. Lift up the copper electrode.

5. Pour kitchen grade vinegar into the cell to immerse the titanium plates. Then

put the copper electrode back in the cell, soak them for about one hour until

no colored areas remain.

6. Open one side of the cell cover (30), drain and properly dispose of the vinegar.

Connect the hose which goes from the pool to the cell. Flush the cell with the

pool water.

7. Reverse steps 3, 4, 5 and 6 to reconnect the electrolytic cell.