Encore woodburning stove, Wall shield requirements for common installations – Vermont Casting 2550 User Manual
Page 16
16
Encore Woodburning Stove
2000956
Wall Shield Requirements for Common Installations
E
E
C
B
A
B
D
ST629a
Encore
wall shield AA
02/01
E
E
A = 30” (762mm)
B = 44” (1118mm)
C = 36” (910mm)
D = 66” (1676mm)
E = 1” (25mm)
ST629a
Fig. 23 Parallel installation, vertical chimney connector,
with stove, connector and wall shields. Maximum reduction
for both rear and side wall. Wall shields may meet at corner if
desired. A heat shield 24” (610mm) in diameter suspended 1”
(25mm) below the ceiling must surround the chimney.
A
B
C
B
A
C
ST630
Enc
Wall shield
B
02/01
A = 48” (1219mm)
B = 36” (910m)
C = 1” (25mm)
ST630
Fig. 24 Parallel installation with rear wall pass-through,
two wall shields. Reduced clearances to both rear and side
walls. Wall shields may meet at corner if desired. Shielding for
connector is centered behind connector. Wall pass-through
must comply with codes. (See “Special Installations”)
B
C
D
A
C
ST630a
Encore
Wall shield
BB
02/01
E
F
F
A = 30” (762mm)
B = 23” (584mm)
C = 44” (1118mm)
D = 66” (1676mm)
E = 36” (910mm)
F = 1” (25mm)
ST630a
Fig. 25 Parallel installation with rear wall pass-through
with stove, connector and wall shields. Wall shields may
meet at corner if desired. Connector shield extends 28”
(710mm) above flue collar, or to the elbow whichever is less.
Height “D” must be 66” (1676mm) or reach the thimble. Pass-
through must comply with codes. (See “Special Installations”.)
B
A
D
E
C
E
D
A
ST631
Encore
Wall shield
C
02/01
B
E
E
A = 29” (737mm)
B = 45” (1143mm)
C = 16” (406mm)
D = 36” (910mm)
E = 1” (25mm)
ST631
Fig. 26 Corner installation, vertical chimney connector,
with rear, stove, connector and wall shields. Wall shields
MUST meet at corner. Connector heat shield extends 28”
(710mm) above flue collar. A 24” (610mm) diameter ceiling
heat shield must surround the chimney and be suspended 1”
(25mm) from ceiling.
B
A
D
E
C
E
D
A
ST631a
Encore
Wall shield
CC
02/01
B
E
E
A = 29” (737mm)
B = 45” (1143mm)
C = 16” (406mm)
D = 36” (910mm)
E = 1” (25mm)
ST631a
Fig. 27 Corner installation, vertical chimney connector,
two wall shields. Reduced side clearances. Wall shields
MUST meet at corner.
E
E
C
B
A
B
D
ST629
Encore
wall shield
02/01
A = 30” (762mm)
B = 48” (1219mm)
C = 66” (1676mm)
D = 36” (910mm)
E = 1” (25mm)
ST628
Fig. 22 Parallel installation, vertical chimney connector,
two wall shields. Reduced clearances for both rear and side
walls. Wall shields may meet at corner if desired. Shielding for
connector is centered behind connector.