beautypg.com

Encore woodburning stove, Wall shield requirements for common installations – Vermont Casting 2550 User Manual

Page 16

background image

16

Encore Woodburning Stove

2000956

Wall Shield Requirements for Common Installations

E

E

C

B

A

B

D

ST629a

Encore

wall shield AA

02/01

E

E

A = 30” (762mm)

B = 44” (1118mm)

C = 36” (910mm)

D = 66” (1676mm)

E = 1” (25mm)

ST629a

Fig. 23 Parallel installation, vertical chimney connector,

with stove, connector and wall shields. Maximum reduction

for both rear and side wall. Wall shields may meet at corner if

desired. A heat shield 24” (610mm) in diameter suspended 1”

(25mm) below the ceiling must surround the chimney.

A

B

C

B

A

C

ST630

Enc

Wall shield

B

02/01

A = 48” (1219mm)

B = 36” (910m)

C = 1” (25mm)

ST630

Fig. 24 Parallel installation with rear wall pass-through,

two wall shields. Reduced clearances to both rear and side

walls. Wall shields may meet at corner if desired. Shielding for

connector is centered behind connector. Wall pass-through

must comply with codes. (See “Special Installations”)

B

C

D

A

C

ST630a

Encore

Wall shield

BB

02/01

E

F

F

A = 30” (762mm)

B = 23” (584mm)

C = 44” (1118mm)

D = 66” (1676mm)

E = 36” (910mm)

F = 1” (25mm)

ST630a

Fig. 25 Parallel installation with rear wall pass-through

with stove, connector and wall shields. Wall shields may

meet at corner if desired. Connector shield extends 28”

(710mm) above flue collar, or to the elbow whichever is less.

Height “D” must be 66” (1676mm) or reach the thimble. Pass-

through must comply with codes. (See “Special Installations”.)

B

A

D

E

C

E

D

A

ST631

Encore

Wall shield

C

02/01

B

E

E

A = 29” (737mm)

B = 45” (1143mm)

C = 16” (406mm)

D = 36” (910mm)

E = 1” (25mm)

ST631

Fig. 26 Corner installation, vertical chimney connector,

with rear, stove, connector and wall shields. Wall shields

MUST meet at corner. Connector heat shield extends 28”

(710mm) above flue collar. A 24” (610mm) diameter ceiling

heat shield must surround the chimney and be suspended 1”

(25mm) from ceiling.

B

A

D

E

C

E

D

A

ST631a

Encore

Wall shield

CC

02/01

B

E

E

A = 29” (737mm)

B = 45” (1143mm)

C = 16” (406mm)

D = 36” (910mm)

E = 1” (25mm)

ST631a

Fig. 27 Corner installation, vertical chimney connector,

two wall shields. Reduced side clearances. Wall shields

MUST meet at corner.

E

E

C

B

A

B

D

ST629

Encore

wall shield

02/01

A = 30” (762mm)

B = 48” (1219mm)

C = 66” (1676mm)

D = 36” (910mm)

E = 1” (25mm)

ST628

Fig. 22 Parallel installation, vertical chimney connector,

two wall shields. Reduced clearances for both rear and side

walls. Wall shields may meet at corner if desired. Shielding for

connector is centered behind connector.