Zone patterns, Wiring, 18 zones 36 beams – Interlogix 6250FM Series User Manual
Page 3: 29 zones 58 beams ceiling mount–center spot mask

ZONE PATTERNS
With "Vertical Barrier" Mask
Wall Mount–No Mask
With "Pet Alley" Mask
Strip back the outer jacket on your wiring cable. This will
allow wires to flex in the case. Use cable strain relief built
into back cover to prevent stressing wires at their connec-
tion.
With "Single Spot" Mask
Wiring
1 Zone
2 Beams
29 Zones
58 Beams
7 Zones
14 Beams
7 Zones
14 Beams
With "Wide Angle" Mask
Side View
18 Zones
36 Beams
Side View
29 Zones
58 Beams
Ceiling Mount–Center Spot Mask
Capture
Zone
25' diameter (7.5m)
coverage pattern
8' (2.4m)
Note: Intruder must enter capture zone in order to be detected. False alarm sources,
such as heaters, should be kept out of the coverage pattern. Be sure to insert center
spot mask to reduce potential for false alarms.
15' (4.59m) X 20' (6.12m)
capture zone
Note: The unit should be connected to a UL listed power
supply, capable of providing four hours of standby power.
Side View
30'
9.14m
40'
12.19m
38.4°
0'
7'
2.13m
0'
10'
3.04m
20'
6.09m
30'
9.14m
40'
12.19m
+54°
+38.4°
+18°
54°
20°
0°
54°
38.4°
20°
90°
0'
30'
(9.14m)
40'
(12.19m)
40'
12.19m
7'
2.13m
10°
40'
12.19m
0'
40'
12.19m
0'
7'
2.13m
7°
Top View
10'
3.04m
30'
9.14m
20'
6.09m
Top View
5.9°
Top View
0'
10°
40'
12.19m
0'
40'
12.19m
10'
3.04m
20'
6.09m
30'
9.14m
7'
2.13m
Top View
Side View
Note: Lens must be
inverted for pet alley
90°
30'
9.14m
40'
12.19m
3'
.91m
40'
12.19m
0'
Side View
0'
10'
3.04m
20'
6.09m
30'
9.14m
Top View
30'
9.14m
20'
6.09m
10'
3.04m
0'
+
–
+
–
Power-In
7 to 16 VDC
Power-In
7 to 16 VDC
6255FM Model
6257FM Model
NC COM
NO COM T/NO Tamp
3