Installing the sureshot – Interlogix 6250 Series User Manual
Page 2
Avoid False Alarm Sources
Sunlight or
reflected sunlight
Pets
Intermittent
heat sources
Hot or cold air
directed onto sensor
6. Choose which masking plate you need, if any. Insert
behind lens on front cover by pressing over four mounting
pins. Once front cover is installed the masking plate will be
held tight against the lens.
Note: Masking plates have two notches to prevent
incorrect installation. One notch matches a rib
in the front cover. The second notch matches a
dimple in the lens.
INSTALLING THE SURESHOT
1. Remove front cover by gently prying apart at bottom. Front
cover hinges at top.
2. Remove circuit board assembly by holding pyro shield and
pulling out of back cover.
3. Mount back cover to ceiling, wall or corner. For wall
mounting, make sure "up" arrow is pointing up. Use
appropriate mounting knockouts.
Mounting
UP
MADE IN U.S.A.
1-800-547-2556
Knockouts for
Wall or Ceiling
Mounting
Knockouts for
Corner Mounting
Wiring Knockouts
Wiring Knockouts
Knockouts for
Wall or Ceiling
Mounting
Knockouts for
Wall or Ceiling
Mounting
Knockouts for
Corner Mounting
Knockouts for
Wall or Ceiling
Mounting
4. Snap circuit board assembly back into back cover by
aligning lower edge of board with circuit board guides and
pressing into place.
5. Connect wires per "wiring" diagrams on following page. A
wiring diagram is also included on the inside of the front
cover. You can strain relieve your wire cable by wrapping
it around the strain relief posts in the lower corners of the
back cover.
Note: To correctly mount the Pet Alley Mask, the lens
must be removed from the front cover and
rotated 180
o
.
7. Replace front cover.
Note:
When mounting on the ceiling, align the unit to
maximize the oblong detection pattern for the room.
Capture zone
at 8' (2.4m) mounting height
8. After walk testing, the LED cover can be slid up to cover
the LED.
Note: Unit should be walktested monthly to ensure continual
20' (6.12m)
WIDE
ANGLE
Align notch
with dimple
Inside of
Front Cover
Align notch
with rib
PET
ALLEY
ROTATE LENS
180
o
Rotate
Lens 180°
Inside of
Front Cover
Align notch
with dimple
For false-alarm-free operation, a PIR should not “see"
sources of heat or cold.
15'
(4.59m)