Sensor group characteristics

Table 10 below shows what the sensors on your Concord 4 system do. Every sensor is assigned to a group, and this
table specifies those groups and functions. Every device must be assigned to one of these groups.

Note:

The “X” marks in the table represent characteristics present in a group.

Table 10: Sensor group characteristics

Num ber Nam e

Application

Alarm

Delay

Restoral

Supervisor
y

CS
report

Chim e
(level)

Active
(level)

00

Fixed panic

24-hour audible fixed emergency
buttons

Police

Instant

X

X

1, 2, 3

01

Portable
panic

24-hour audible portable emergency
buttons

Police

Instant

X

1, 2, 3

02

Fixed panic

24-hour silent fixed emergency
buttons

Silent

Instant

X

X

1, 2, 3

03

Portable
panic

24-hour silent portable emergency
buttons

Silent

Instant

X

1, 2, 3

04

Fixed
auxiliary

24- hour auxiliary sensor, such as
pendant panic or holdup button

Auxiliar
y

Instant

X

X

1, 2, 3

05

Fixed
auxiliary

24-hour auxiliary emergency button,
siren shutoff confirms CS report

Auxiliar
y

Instant

X

X

1, 2, 3

06

Portable
auxiliary

24-hour portable auxiliary alert
button

Auxiliar
y

Instant

X

1, 2, 3

07

Portable
auxiliary

24-hour portable auxiliary button,
siren shutoff confirms CS report

Auxiliar
y

Instant

X

1, 2, 3

08

Special
intrusion

Special belongings, such as gun
cabinets and w all safes

Police

Instant

X

X

X

1, 2, 3

09

Special
intrusion

Special belongings, such as gun
cabinets and w all safes

Police

Standard

X

X

X

1, 2, 3

10

Entry/exit
delay

Entry and exit doors that require a
standard delay time

Police

Standard

X

X

X

X

2, 3

11

Entry/exit
delay

Garage doors and entrances that
require extended delay time

1

Police

Extended

X

X

X

X

2, 3

12

Entry/exit
delay

Drivew ay gates and entrances that
require a tw ice extended delay time

1

Police

Tw ice
extended

X

X

X

X

2, 3

13

Instant
perimeter

Exterior doors and w indow s

Police

Instant

X

X

X

X

2, 3

14

Instant
interior

Interior doors (hardw ired)

Police

Follow er

X

X

X

2, 3

15

Instant
interior

Interior PIR motion sensors

1

(RF

w ireless)

Police

Follow er

X

X

2, 3

16

Instant
interior

Interior doors (hardw ired)

Police

Follow er

X

X

X

3

17

Instant
interior

PIR motion sensors 1 (RF w ireless) Police

Follow er

X

X

3

18

Instant
interior

Instant interior cross-zone # PIR
motion sensors

1 2

Police

Follow er

X

X

3