beautypg.com

Programming – Interlogix Concord 4 REV C Installation Manual User Manual

Page 4

background image

4

Concord 4 Installation Guide

Grounding the panel

For maximum protection from lightning strikes and

transients, connect the enclosure to earth ground. Use
16-gauge, solid copper wire from an earth grounded cold
water pipe clamp to the enclosure. For best results , we
recommend that you crimp a spade lug on the wire end
at the panel and secure the lug to the enclosure.

Antenna shrouds

Install a plastic antenna shroud (included with the panel)
over each antenna and snap them into the holes on top
of the enclosure (skip this step for hybrid and
commercial systems).

Programming

For onsite system programming, you must have an
alphanumeric touchpad.

You must use an installer/dealer code (default 4321) to
enter program mode. You may place the system into
programming mode only when you disarm all partitions.

Note:

If the system is powered up after the programming

touchpad is connected or if a bus command scan is
executed, the programming touchpad will be learned
(programmed) into the system and must later be
manually deleted.

To enter program mode:

1. Make sure you disarm the system in all partitions.

2. Press 8, 4321, 0, 0.

The display shows SYSTEM PROGRAMMING.

To enter program mode using a programming
touchpad:

1. Connect the red, black, green, and white wires from

the programming touchpad cable (60-791) to the
power and bus wires/terminals on an alphanumeric
touchpad, matching the +12V (red), Bus A (green),
Bus B (white), and GDN (black) on each.

2. Make sure the system is powered up and disarmed.

3. Connect the plug on the cable onto the panel

programming touchpad header.

4. Press 8, 4321, 0, 2.

The touchpad sounds one short beep.

5. Press * and verify that the display shows SERVICE

TOUCHPAD ACTIVE.

6. Press 8, 4321, 0, 0.

The display shows SYSTEM PROGRAMMING.

7. After programming is complete, disconnect the

touchpad from the panel header.

Touchpad programming options

In program mode, touchpad buttons let you navigate to
all installer programming menus for configuring the
system.

Table 6 below describes the touchpad button functions
in program mode.

Table 6: Touchpad programming functions

Button

Programming function

#

Select menu item or data entry.

*

Deselect menu item or data entry (if pressed
before #).

A ()

B ()

Scroll through available option at the current
menu tier. Scroll through sensor text options
during sensor text programming.

C

Enter pauses w hen programming phone
numbers.

D

Delete certain programming settings.

0 to 9

Enter numeric values w herever needed.

1 and 2

Select off (1) or on (2) w herever needed.

1 to 6

Press and hold to enter alphabetical characters A
through F for account numbers.

7 and 9

Press and hold to enter * (7) or # (9) for phone
numbers.

Menu navigation

There are two basic tiers of programming menus, tier 1

and tier 2.

From the tier 1 System Programming menu, you can
access the following tier 2 programming menus:

Security

Phones

Phone options

Timers

Light controls

Touchpad options

Reporting

Siren options

Sensors

Audio verification

Accessory modules

Onboard options

Macro keys