beautypg.com

Specifications, Regulatory information – Interlogix Simon XTi CDMA Module V4 User Manual

Page 9

background image

Simon XT/XTi CDMA Module V4 Installation Instructions

9

other commands.)

---- Replicate Mode

2

Initiates replicate mode on the panel.

---- Send Node Info

2

For advanced use only. Do not use

unless directed to do so by Alarm.com.

---- Refresh Thermostat

2

Requests updated thermostat data.

1 I

All Image Sensor menus are only available when an Image Sensor

daughterboard has been connected to the module. An Image Sensor

daughterboard is required to enable Image Sensor functionality. For use

with Simon XTi only

2

Refer to the emPower

TM

installation instructions and guides on the

Alarm.com Dealer Site for more information on Z-Wave enrollment and

troubleshooting.

Walking the Customer through New User Setup on the
Web

This section describes how to help your customer set up their
website account, and only applies to customers on an interactive
service plan with an online account. (Skip this step if the customer
is using the module for wireless signaling only).

Before the customer can configure their website account, the
Alarm.com account for that customer must be created on the
Dealer Site, and the CDMA module associated with the account
must be installed successfully.

To log in and access their account, the customer can go to
www.alarm.com (or custom dealer website address) to complete
the new subscriber setup procedure.

The customer will need the following:

• The website login and temporary password included on the

Alarm.com Welcome Letter generated when the account
was created by the Dealer

• A list of their system sensors and touch screens with

corresponding zone IDs

• At least one phone number and e-mail address where

notifications can be sent

Note: At least one sensor must be learned into the panel to
complete the new subscriber setup. If not all sensors and touch
screens were learned in before powering up the module, an
updated sensor list must be requested by performing a CDMA
phone test or requesting an updated equipment list from the
Dealer Site.

Specifications

Compatibility

Simon XT panels with software versions 0.0.H

and later and Simon XTi

Power requirements

6V nominal

Peak current

1.7A

Operating temperature 32 to 120°F (0 to 49°C)

Storage temperature

-30 to 140°F (-34 to 60°C)

Max. relative humidity 90% non-condensing

Cellular network dual

band

CDMA/1xRTT

Dimensions

4 1/16 x 1 7/8 in. (H x W)

Listings

FCC Part 15, Verizon Certified

Regulatory information

Changes or modifications not expressly approved by Alarm.com
can void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by
one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different

form that which the receiver is connected

• Consult the dealer or an experienced radio/TV technician for

help.

Operation is subject to the following two conditions:

(1) This device may not cause interference

(2) This device must accept any interference, including
interference that may cause undesired operation of the device

This equipment complies with the FCC RF radiation exposure limits
set forth for an uncontrolled environment. This equipment should
be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.

FCC IDs: YL6-143200C5V4
If equipped with Image Sensor daughterboard, FCC ID: YL6-
143200C5V4IS

This device contains FCC ID: RI7CC864-DUAL, IC: 5131A-CC864-
DUAL