600-1053-4 Concord 4 CDMA Module Installation Sheet

hours in advance of installation to ensure that the radio is

activated prior to installation.

To activate an account go to www.alarm.com/dealer and login.
Under the “Customers” heading at the top left of the page click
on “Create New Customer”. You will need the following
customer information to create the account:

Customer Name

Customer Address

Customer Phone Number

Customer E-mail

Preferred login name for the customer

Alarm.com Module Serial Number

At the end of the account creation process you will be able to

print a Welcome Letter for the customer that has their login

information and temporary password for the Alarm.com

website.

Installation

Before you install the system, the module must be activated.

The account creation process automatically activates the

module within 24 hours.

The module draws a maximum of 65 mA (continuous) from the

panel in power save mode, and 100 mA (continuous) from the

panel in idle and connected modes. Do not exceed the panel

total output power when using panel power for bus devices and

hardwired sensors (refer to the panel documentation).

Use four-conductor, 22 or 18 gauge stranded wire to connect

the module to the panel. Table 2 below shows the maximum

wire length for each gauge.

Table 2: Maximum wire length

Gauge

Maximum wire length to panel

22 gauge

40 ft. (12.2 m)

18 gauge

90 ft. (27.4 m)

You will need the following tools and supplies to install the

module:

Small blade and Phillips screwdrivers

Drill and bits for screws and/or anchors

Wire cutter/stripper

Four-conductor, 22-gauge or larger stranded wire

#6 panhead screws (4 included)

Wall anchors (four included)

2-Kohm EOL resistor (included)

Use the following guidelines to choose a location for the

module:

Check the signal strength before choosing a location. Do a

walking signal strength test by powering the module off the

battery directly (connect the GND and +12V terminals).

After 2 minutes, cellular status LED 4 will flash between

one and five times, equivalent to the number of bars on a

cell phone. We recommend a signal level of two or higher.

Do not the mount the module inside the panel’s metal
enclosure or within 6 ft. (1.8 m) of panel.

Avoid mounting the module in areas with excessive metal

or electrical wiring, such as furnace or utility rooms.

Locate the module near an outside wall, preferably on an

upper level.

For homes or businesses located in canyons or with hills

nearby, it is necessary to place the antenna higher in the

building.

Caution:

You must be free of static electricity before handling

electronic components. Touch a grounded metal surface

before touching the circuit board.

To mount the module:

1. Press down on the top of the enclosure cover, remove it,

and set it aside.

2. Snap the antenna onto the antenna connector (see

Figure 1 on page 1). To connect the antenna, place one of

your thumbs or fingers behind the antenna connector.

With your other hand, press the end of the micro miniature

coaxial connector (MMCX) into the antenna connector

until you hear a slight click.

3. Place the backplate on the wall at the desired mounting

location, check for level, and mark the three mounting

holes and the wire access area (see Figure 1 on page 1).

4. To avoid placing unnecessary strain on the antenna

connector, which can damage the module, use either of
the following orientations shown in Figure 2.