IC Realtime 4 Channel PoE Mobile Network Video Recorder User Manual
Page 27

18
3.6.3
Alarm Output Port
2 ways relay alarm output (NO contact). Provide external power to external alarm device.
To avoid overloading, please read the following relay parameters sheet carefully.
RS485 A/B cable is for the A/B cable of the PTZ decoder.
Relay Specification
Model: HFD23
Contact
Parameter
Contact mode
1Z
Contact resistance
100m
Ω
(0.1A 6VDC)
Contact material
AgNi+gold-plating
Contact
0.5A 125VAC/1A 30VDC
Max switch voltage
125VAC / 60VDC
Max switch current
2A
Max switch power
62.5VA/30W
Min allowed load
1mA 5V
Mechanical durability
1x10
7
(300/min)
Electric durability
1x10
5
(30/min)
Performance
Parameter
Insulation resistance
1000M
Ω
(500VDC)
Media
pressure
Between
loop
and
contract
1000VAC 1min
Between
separated
contact
400VAC 1min
Operation time (Rated
voltage)
)
≤
5ms
Release time (Rated
voltage)
≤
5ms
Bound
time
(Rated
voltage)
About 5ms
Loop
temperature
rise(Rated voltage)
≤
65K
Strike
98m/s2
Vibration
10Hz~55 Hz 3.3mm Double amplitude
Humidity
98% RH, 40
℃
Temperature
-30
~70
℃
℃
Weight
About 2.2g
leading-out end mode
DIP