beautypg.com

Volume control table – Galaxy Audio DS-SP24 User Manual

Page 36

background image

● USB/RS485 Remote Control protocol for Preset Changing and Gain/Volume controls

The following is the HEX Code for controlling the DS-SP24 recall presets and master volume
control:

Preset Changing:

CMD_RECALL_PRESET: CMD=1BH

A. The User has to send the following Command, including the number of the preset to load on the
unit:

TX:

XX = 0,..,31 (ID device)
Npreset=0,...,23 Presetnumber

The DS-SP24's microcontroller will check if the Preset is initialized (available or not yet created...)

B. If YES, then the microcontroller will send back to the User (eg Crestron/AMX Remote Control..)
the same frame used by the command.

RX:

So in this case, if the user gets back EXACTLY what was sent, the preset is existing and loaded on
the unit.

C. If the preset that the user wanted to load is NOT YET INITIALIZED (not yet created, so not
Available...), the microcontroller will notify that to the user, sending back the following frame:

RX:

STX

ID_M

ID_N

CMD

D0

D1

D2

D3

D4

D5

D6

D7

ETX

F0H

C1H

XX

1BH

NPreset

00H

00H

00H

00H

00H

00H

00H

F7H

STX

ID_M

ID_N

CMD

D0

D1

D2

D3

D4

D5

D6

D7

ETX

F0H

C1H

XX

1BH

NPreset

00H

00H

00H

00H

00H

00H

00H

F7H

STX

ID_M

ID_N

CMD

D0

D1

D2

D3

D4

D5

D6

D7

ETX

F0H

C1H

XX

1BH

FFH

00H

00H

00H

00H

00H

00H

00H

F7H

Volume Control Table

35