Note: Once the desired High Shelving filter is selected, the “PM3” can then be used to select the
desired GAIN and when the GAIN is set at a value different from 0.0dB, then the filter type cannot
be changed until this GAIN is returned to 0.0dB.
Once in the High Shelving Filter's edit screen all the filter's parameters can be modified using the
“NAV/PM1”, “PM2” and “PM3” encoders for editing the Filter's Low Cut Frequency, Filter's Order
and Gain.
The Lo Cut Frequency of the High Shelving Filter can be edited using the “NAV/PM1” encoder, the
Filter's Order can be adjusted by the “PM2” encoder and the Gain the “PM3” encoder:
“Lo Cut Frequency ”: the selectable frequencies range is from 20Hz to 20kHz in steps of 1/24 of an
Octave and can be adjusted by rotating the “NAV/PM1” encoder.
“High Shelving Order”: the selectable High Shelving Filter's range can be selected between the
1st (Lo-1st.) and the 2nd (Lo-2nd.) one.
“Gain”: the selectable range of the Gain is from -15dB to +15dB in steps of 0.5 dB and can be
adjusted by rotating the “PM3” encoder.
Note1: Once the desired options have been selected using the 3 encoders, they are automatically
saved as current and stored in the DS-SP24 system status once leaving the page.
Note2: To exit this page, push the “ESC” button.
Vu-Meter page – from this page it is possible to select what is shown on the Output LED meters, by
using the “PM1” or “PM2” encoders.
The outputs' LED meters can show the Output signal LEVEL or the Output Limiters' activity.
When the Limiters' activity is selected, the LED meters will show, from top down, the activity of
the Limiter available on the output.
When the Output signal Level selected, the LED meters will show, from bottom up, the level of the
signal:
Name page – from this screen it is possible to assign a 6 character name to the Output Channel.
The following is an example screen for a “Name” page labeled “Low” for Output Channel 1:
Out-1 Name Vu-Meter
-> Vu-Meter = Limiter Act
Out-1 Name Vu-Meter
-> Vu-Meter Level
Out-1 Low Name
Name = Low