REFSET - Reference channel setup
This command selects/reports the output the reference channel tracks.
Command form: DEVICE REFSET
Argument details
Name
Description
Device
0–7 or * to select all units
REFSET
Command
Channel
1–4 (select Virtual Reference number)
Group
1–9 (select output channel to track)
Value
0 = none
Example:
#53 REFSET 2 4 On XAP 800 unit 3 (#53), virtual reference (2) will
track gain changes mde on output channel 4.
SERECHO - Serial Echo
This command selects/reports the serial echo of the RS-232 port.
Command form: DEVICE SERECHO [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SERECHO
Command
Channel
See Groups and Channels, page 97
Value
0 = Off, 1 = On, 2 = Toggle, Null = Current state
Example:
#54 SERECHO 1 On XAP 800 unit 4 (#54), the serial echo
(SERECHO) of the RS-232 port is set to on (1).
SERMODE - Serial Mode
This command selects/reports the serial mode of the RS-232 port.
Command form: DEVICE SERMODE [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SERMODE
Command
Value
1 = Text, 2 = Binary, Null = Current mode
Example:
#55 SERMODE 1 On XAP 800 unit 5 (#55), the RS-232 port serial
mode (SERMODE) is set to text (1).
Appendices
~ Appendix E: Serial Commands
If the serial mode is
changed, the terminal will
not see a response from
the unit, nor will the unit respond to
commands until the new status is
matched by the terminal.
✍