Configuration, Hardware points – Carrier AQUAZONE 50RLP User Manual
Page 21
![background image](/manuals/67660/21/background.png)
21
CONFIGURATION
The Aquazone™ System Control Panel contains a Comfort
Controller 6400 programmed using the standard algorithms
and enhanced by BEST++™ custom programming. The
BEST++ Templates for some of the programs have been
removed to prevent field alterations. For other programs,
the templates are included to allow for jobsite customization.
For basic information about the algorithms please refer to the
Comfort Controller Overview and Configuration manual
(808-891). Default configurations are listed later in this section.
Hardware Points —
The hardware points are shown in
Table 11 and 12.
Table 11 — Hardware Points 1 to 32 (HWP01-32)
Table 12 — Hardware Points 33 to 64 (HWP33-64)
LOOP WATER FLOW SWITCH — This discrete input is
used to provide a signal that one of the loop water pumps is on.
If both pumps have been commanded to run and no water flow
is detected, then the system water source heat pumps will
run in the fan only mode for DDC (Direct Digital Control)
coordinated heat pump controllers, while the system relays for
thermostat systems will be turned off.
Loop Water Flow Switch:
Display Units
Discrete ASCII
Default Value
No
Display Range
Yes/No
Network Access
Read/Write
SYSTEM SUPPLY WATER TEMPERATURE — The sys-
tem supply water temperature is the temperature of the water
being pumped to the system of water source heat pumps. The
temperature is measured by a 10K Thermistor (MCI). This
output and sensor is required for proper function of the loop
and heat pumps.
System Supply Water Temperature:
Display Units
degrees F (degrees C)
Default Value
–40.0
Display Range
–40.0-245.0
Network Access
Read/Write
SYSTEM RETURN WATER TEMPERATURE — The sys-
tem return water temperature is the temperature of the water
returning from the system of water source heat pumps. This
temperature measured by a 10K Thermistor (MCI). This output
and sensor is provided for informational purpose and indicates
the average load caused by the normal operation of the heat
pumps.
System Return Water Temperature:
Display Units
degrees F (degrees C)
Default Value
–40.0
Display Range
–40.0-245.0
Network Access Read/Write
SYSTEM WATER PRESSURE — This sensor is used to
measure the pressure of the supply water to the system of water
source heat pumps. This sensor should be located
2
/
3
of the way
down the supply water distribution piping or in a location that
will provide a good reference of the supply water pressure.
This sensor is used to control the speed of variable frequency
drives pumping water to the water source heat pumps. Each
water source heat pump may be equipped with a two position
isolation valve that may be closed when the compressors are
not energized in order to reduce the quantity of water being
pumped through the system.
System Water Pressure:
Display Units
in. wg
Default Value
0.0
Display Range
0.0-5.0
Network Access Read/Write
DESCRIPTION
VALUE
NAME
Loop Water Flow
Yes
FLOW
System Supply Water Temp
60.3 dF
SSWT
System Return Water Temp
51.0 dF
SRWT
System Diff. Pressure
0.00 PSIG
SDP
Remote Occupancy Mode
Off
RMTOCC
System
Enable
ALLSYS
Override Input Zone 1
On
OVRIZ1
Override Input Zone 2
On
OVRIZ2
Pump Number 1 Speed
100.0%
PUMP1
Pump Number 2 Speed
0.0%
PUMP2
Cooling Tower 1 Level
0.0%
CTL1
Cooling Tower 2 Level
0.0%
CTL2
Boiler 1 Level
83.2%
BLRL1
Boiler 2 Level
0.0%
BLRL2
System for Zone 1
Enable
SYSZ1
System for Zone 2
Enable
SYSZ2
Override Input Zone 3
Off
OVRIZ3
Override Input Zone 4
Off
OVRIZ4
Override Input Zone 5
Off
OVRIZ5
Override Input Zone 6
Off
OVRIZ6
Override Input Zone 7
Off
OVRIZ7
Override Input Zone 8
Off
OVRIZ8
Override Input Zone 9
Off
OVRIZ9
Override Input Zone 10
Off
OVRIZ10
System for Zone 3
Disable
SYSZ3
System for Zone 4
Disable
SYSZ4
System for Zone 5
Disable
SYSZ5
System for Zone 6
Disable
SYSZ6
System for Zone 7
Disable
SYSZ7
System for Zone 8
Disable
SYSZ8
System for Zone 9
Disable
SYSZ9
System for Zone 10
Disable
SYSZ10
DESCRIPTION
VALUE
NAME
Override Input Zone 11
Off
OVRIZ11
Override Input Zone 12
Off
OVRIZ12
Override Input Zone 13
Off
OVRIZ13
Override Input Zone 14
Off
OVRIZ14
Override Input Zone 15
Off
OVRIZ15
Override Input Zone 16
Off
OVRIZ16
Override Input Zone 17
Off
OVRIZ17
Override Input Zone 18
Off
OVRIZ18
System for Zone 11
Disable
SYSZ11
System for Zone 12
Disable
SYSZ12
System for Zone 13
Disable
SYSZ13
System for Zone 14
Disable
SYSZ14
System for Zone 15
Disable
SYSZ15
System for Zone 16
Disable
SYSZ16
System for Zone 17
Disable
SYSZ17
System for Zone 18
Disable
SYSZ18