beautypg.com

Commands description, System diagnosis commands – id, iv, is, sr, Id get device identity – Flintec LDU 69.1 User Manual

Page 13: Iv get firmware version, Is get device status, Sr reset ldu xx.x firmware, Rs read serial number

background image

LDU 69.1 Technisches Handbuch, Rev. 12 January 2011

Page 13 of 28

8. Commands

Description

For better clarity, all commands are divided into groups as described on the following pages.

8.1. System

Diagnosis

Commands – ID, IV, IS, SR

Use these commands you get the LDU XX.X type, firmware version or device status. These commands are
sent without parameters.

8.1.1. ID

Get Device Identity

Master (PC / SPS) sends

Slave (LDU XX.X) responds

ID

D:6910

The response to this request gives the actual identity of the active device. This is particularly useful when trying
to identify different device types on a bus.

8.1.2. IV

Get Firmware Version

Master (PC / SPS) sends

Slave (LDU XX.X) responds

IV

V:0232

The response to this request gives the firmware version of the active device.

8.1.3. IS

Get Device Status

Master (PC / SPS) sends

Slave (LDU XX.X) responds

IS

S:067000

(example)

The response to this request comprises of two 3-digit decimal values (067 and 000), which can be decoded
according to the table below:

Leftmost 3-digit value

Rightmost 3-digit value

1 Signal stable (no motion)

1 (not used)

2 Zeroing action performed

2 (not used)

3 Tare active

3 (not used)

4 (not used)

4 (not used)

8 (not used)

8 (not used)

16 (not used)

16 (not used)

32 (not used)

32 (not used)

64 (not used)

64 (not used)

128 (not used)

128 (not used)

The example decodes the result S:005000 as follows:

Signal stable (no motion) [2

0

= 1, LSB]

Zeroing action not performed [= 0]

Tare is active [2

2

= 4]

Note:

The bits that are not used are set to zero.

8.1.4. SR

Reset LDU XX.X Firmware

Master (PC / SPS) sends

Slave (LDU XX.X) responds

SR

OK

This command will respond with ‘OK’ and after maximum 400 ms perform a complete reset of the LDU. It has
the same functionality as power off and on again.

8.1.5. RS

Read Serial Number

Issuing the RS command will return the current serial number in the format S:12345678.

Master (PC / SPS) sends

Slave (LDU XX.X) responds

Meaning

RS

S:123456789

Request: RS = 12345678