7.
Commands – Overview
Command Short
description
Parameter
value
Page
AD
Communication: Device Address
0...255
24
BR
Communication: Baud Rate
9600…115200 baud
24
CE
Calibration: Open Calibration Sequence; Read TAC Counter
0...65535
14
CG
Calibration: Set Calibration Gain (span) at load > zero
0...999999
16
CI
Calibration: Minimum Output Value
–999999...0 d
14
CL
Communication: Close Device
None
24
CM n
Calibration: Set Maximum Output Value (n = 1, 2 or 3)
1...999999 d
14
CS
Save the calibration data (CMn, CI, DS, DP, CZ, CG, u.a.) to EEPROM None
17, 25
CZ
Calibration: Set Calibration Zero Point – scale without load
None
15
DP
Calibration: Set Decimal Point Position
0...5
15
DS
Calibration: Set Display Step Size
1, 2, 5, 10, 20, 50,
100, 200
15
DX
Communication: Set Half-duplex (0) or Full-duplex (1)
0 or 1
24
FD
Factory default settings: Write data to EEPROM (TAC protected)
None
16
FL
Digital filter: Filter Settings
0...17
19
GG
Output: Get Gross Value
None
21
GH
Output: Get Hold Weight
None
22
GN
Output: Get Net Value
None
21
GS
Output: Get ADC Sample Value
None
21
GT
Output: Get Tare Value
None
21
GW
Output: Get Data String “Net/Gross/Status“
None
21
HW
Output: Hold weight for time-synchronous capturing
None
22
ID
Device information: Identify Device
None
13
IS
Device information: Identify Device Status
None
13
IV
Device information: Identify Firmware Version
None
13
LC
Linearisation: Clear data
None
16
LN
Linearisation: Define up to 7 calibration points
0...200000 d
17
MR
Calibration: Define Multi-interval (0) or Multi-range (1)
0 or 1
15
NR
Motion detection: No-motion Range
0...65535 d
18
NT
Motion detection: No-motion Time Period
0...65535 ms
18
OP
Communication: Open Device xxx
0...255
24
RS
Device information: Read serial number
None
13
RT
Scale function: Reset tare and switch to gross indication
None
20
RZ
Scale function: Reset zero point
None
20
SG
Auto-transmit: Send Gross Value continuously
None
23
SN
Auto-transmit: Send Net Value continuously
None
23
SR
Reset firmware (warm start)
None
13
ST
Scale function: Set Tare and switch to Net Indication
None
20
SW
Auto-transmit: Send Data String „Net/Gross/Status“ continuously
None
23
SZ
Scale function: Set Zero
None
20
UR
Digital filter: Update Rate
0...7 (= 2
0
bis 2
7
)
19
WP
Save the Setup Data (FL, NR, NT, AD, BR, DX) to EEPROM
None
25
ZR
Calibration: Set Zero range
0...999999
16
ZI
Calibration: Initial Zero Range
0...999999 d
16
ZT
Calibration: Disable (0) or enable (1) Zero tracking
0 or 1
16