2. Digital
mode.
In this mode, the WPTOUCH acts as a MIMO88 slave, being
connected to it by means of the MIMO-REMOTE digital control
bus. The functions of the buttons and control wheel and the
information displayed on the WPTOUCH screen will depend on
the MIMO88 setup. In this mode, control voltage outputs are
disabled.
3. INSTALLATION AND CONNECTION
The WPTOUCH can be recessed in wall, inserted into a
standard electrical box or surface mounted, by means of the provided
bracket.
Connections between the WPTOUCH and other equipment to
be remote controlled are:
1.
Connection with MIMO54 (analogue volume control,
MUTE and source selection). See diagram.
2.
Connection with equipment featuring a 0-10V DC remote
control port for volume (AMPACK series, AMIC and
AMIC24, NZA series, MPA series, etc.). See diagram.
3.
Connection with MIMO88 (digital control, programmable
functions). See diagram.
Note: in some cases, a WP-PSU power supply will be necessary due to the
power consumption requirements of the installation, depending on the type
of device WPTOUCH are connected to and/or the amount of them. In case
of doubt, please contact our technical support.