Ecler CA‐NET RS‐232 User Manual

Ca‐net, Rs‐232 remote control protocol

background image

 

CA‐NET Protocol

 

 

page  1 / 29 

 

ENGLISH VERSION 

CA‐NET

 

RS‐232 Remote Control Protocol  

Updated for CA40, CA200z, DAM514 

 

OCT 2013

 

The built‐in RS‐232 port in the rear panel of the CA and DAM series devices allows for an external 
device communication via a serial connection. This kind of connection uses a syntax which is very 
similar to the one used in the Ecler TP‐NET protocol: it lets a client device get from and/or set the 
values  of  several  parameters  of  a  CA  /  DAM  device  (for  instance,  the  CA40  or  CA200z  digital 
amplifiers or the DAM514 audio digital mixer), like volumes, mutes, equalisation tones, etc. 

The RS‐232 serial communication must fulfil the following specifications: 

 Baud rate:    

9600   (fixed, no auto‐negotiation)

 

 Data bits:  

 

8

 

 Parity:   

 

None

 

 Stop bits:  

 

1

 

 Flow control:   

None

 

 

It’s not allowed to have more than one simultaneous access from several clients to the same CA / 
DAM device using the RS232 connection. 

The  protocol  is  simple  and  direct,  syntax‐friendly,  making  it  easy  to  read,  write  and  modify  the 
generated code. It is based on messages with no begin delimiter: each message is self‐delimited by 
the  RS232  packet  size,  which  is  defined  with  a  maximum  of 

80  ASCII  characters

,  and  always 

including

 

the character 

LF (0x0A) 

at the end of each message. All the messages must be written in 

CAPITAL LETTERS

To  let  some  control  systems  (like  EXTRON®,  CRESTRON®,  AMX®,  RTI®,  VITY®,  MEDIALON®,  etc.) 
process the messages more easily, the CA / DAM device adds the character 

LF (0x0A) 

at the end of 

each message it sends. This way the client of the CA / DAM device can buffer the received messages 
to process them, when required. The CA / DAM device can also handle several messages received in 
a single RS232 packet by using the 

LF

 delimiter.  

The available messages are built with one or more fields separated with blank spaces ( 

 

 = blank 

space): 

  [PARAM1]   [PARAM2]   [PARAM3]   [PARAM4][LF] 

The first field (

TYPE

) defines the message type and then, the required parameters for it (each kind 

of message requires a given number of parameters). The field 

TYPE

 can have these values: