beautypg.com

Caution, Warning – Carrier 58HDX User Manual

Page 4

background image

4

A07691

Center Clip
side-to-side

9”

(228.6 mm)

Fig. 2 -- Bottom Filter Arrangement

A07690

Filter Rack

End Cap

Fig. 3 -- Filter Installed for Side Inlet

f. Remove blower wheel from housing.

UNIT DAMAGE HAZARD
Failure to follow this caution may result in furnace component

failure.
The blower wheel should not be dropped or bent as balance

will be affected.

CAUTION

!

g. Clean wheel per instructions on degreaser cleaner. Do

not get degreaser cleaner in motor.

9. Reassemble motor and blower wheel by reversing items 8b

through 8f. Ensure wheel is positioned for proper rotation.

Be sure to reattach ground wire. Tighten setscrew to 140 to
160 in.--lb torque.

10. Reinstall blower assembly in furnace.
11. Reinstall control box, transformer, and door switch

assembly on blower shelf.

12. Reinstall condensate trap and tubing if previously removed.

a. Reinstall condensate trap in hole in blower shelf.

b. Connect condensate trap drain tubes. See Fig. 6, 7, or 8.

NOTE: Ensure tubes are not kinked or pinched, as this will
affect operation.

c. Connect field drain to condensate trap.

13. Reconnect wires.

Refer to furnace wiring diagram, and connect thermostat leads if

previously disconnected. (See Fig.20.)

UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit component

damage.
Heating speed selection MUST be adjusted to provide proper

temperature rise as specified on the rating plate.

CAUTION

!

Table 1 – Speed Selector

COLOR

SPEED

FACTORY

ATTACHED TO

Black

High

Cool

Orange

Medium High

Heat

Blue

Medium Low

M1

Red

Low

M2

White

Common

Com

14. Turn on electrical supply. Manually close blower access

door switch. Use a piece of tape to hold switch closed.

Check for proper rotation by jumpering R to G.

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury

or death.
Blower access door switch opens 115-v power to furnace

control. No component operation can occur. Caution must be

taken when manually closing this switch for service purposes.

!

WARNING

15. If furnace is operating properly, remove tape to release

blower access door switch, remove jumper across R to G,
and replace blower access door.

Procedure 3 — Cleaning Burners

The following items should be performed by a qualified service

technician. If burners develop an accumulation of light dirt or dust,
they may be cleaned by using the following procedure:

1. Turn off gas and electrical supplies to furnace.
2. Remove main furnace door.
3. Using backup wrench, disconnect gas supply pipe from

furnace gas control valve.

ELECTRICAL SHOCK, UNIT DAMAGE HAZARD
Failure to follow this caution may result in personal injury or

furnace component damage.
Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation.

CAUTION

!

58H

D

X