beautypg.com

Caution, Warning – Carrier 58HDX User Manual

Page 16

background image

16

GASKET

A07828

Fig. 16 -- Gasket on Collector Box

4. Disconnect pressure switch tubes.
5. Disconnect vent pipe from inducer housing outlet by

loosening clamp.

6. Disconnect drain tube from inducer housing. (See Fig. 6 --

14.)

7. Remove inducer housing assembly by removing 4 bolts

attaching assembly to cell panel.

8. Flush inside of collector box with water until discharge

from condensate trap is clean and runs freely.

NOTE: Ensure that drain tube disconnected from inducer housing
is higher than collector box opening or water will flow out tube.

9. Inspect inside area of collector box for any pieces of foreign

materials and remove if present.

UNIT DAMAGE HAZARD
Failure to follow this caution may result in furnace component

damage.
DO NOT use wire brush or other sharp object to inspect or

dislodge materials in secondary heat exchangers as failure of

the secondary heat exchanger may occur. Flush with

water only.

CAUTION

!

10. Reassemble inducer assembly by reversing items 5 through

7. Tighten the vent coupling screw(s) to 15 in.--lb.
of torque.

NOTE: If gasket between inducer housing and collector box is
damaged in any way, it must be replaced. (See Fig. 16.)

11. Refer to furnace wiring diagram and connect wires to

inducer motor and pressure switch or connectors.

12. Reconnect pressure tubes to pressure switch. See diagram

on main furnace door for proper location of tubes. Be sure
tubes are not kinked. (See Fig. 6 -- 14.)

13. Turn on gas and electrical supplies to furnace.
14. Check furnace operation through 2 complete heat operating

cycles. Check area below inducer housing, vent pipe, and
condensate trap to ensure no condensate leaks occur. If leaks
are found, correct problem.

FIRE OR EXPLOSION HAZARD
Failure to follow the warnings could result in personal injury,

death, or property damage.
Never test for gas leaks with an open flame. Use a

commercially available soap solution made specifically for the

detection of leaks to check all connections.

!

WARNING

15. Check for gas leaks.
16. Replace main furnace door.

Procedure 6 — Servicing Hot Surface Igniter

The igniter does NOT require annual inspection. Check igniter

resistance before removal.

1. Turn off gas and electrical supplies to furnace.
2. Remove main furnace door.
3. Disconnect igniter wire connection.

58H

D

X