Cabletron Systems SPECTRUM TRMMIM User Manual
Page 61

Viewing Station-specific Information
3-11
Ring Map
Open Status
This field displays the result of the last “open” command or the last attempt by 
the management station to open onto the ring: whether the management station 
did in fact open onto the ring, or if an error occurred. This field may display any 
one of the following:
No Open
An open command has not been issued.
Bad Param
The open command could not be completed because the 
parameters did not allow for the station to be opened 
onto the ring.
Lobe Test Failed
The lobe media check has failed for the management 
station.
Signal Loss
A signal loss condition has been detected at the 
management station’s receiver input during the open 
process.
Insertion Timeout
The management station has failed to logically insert on 
the ring before the insertion timer expires.
Purge Failed
The management station has timed out when attempting 
a ring purge after becoming the active monitor: that is, 
the management station was unable to receive its own 
ring purge MAC frames.
Beaconing
The management station received a beacon MAC frame 
after physically inserting into the ring.
Duplicate MAC
Another station on the ring has the same MAC address
Address
as the management station.
Parameter Requested
 The management station has determined that a Ring 
Parameter Server (RPS) is present on the ring, but it does 
not respond to a request initialization MAC frame.
Remove Received
The management station received a remove adapter 
MAC frame during the insertion process.
Open
The open command was completed successfully.
Error Status
This field displays a number associated with the most recent error status that was 
reported by the management station. It is possible for more than one error status 
to be reported at one time; in this case, the number displayed would be the sum of 
the codes of the last errors recorded. The following table lists the possible errors 
and their corresponding error codes: