beautypg.com

D.A.S. Audio Aero User Manual

Page 8

background image

2.3 SAFETY FACTORS

breaking load limit and the

maximum safe working load limit (SWLL). In this
case, the breaking load limit of each of the flying
points is 4,000 kg (8,820 lbs) as determined by
destructive testing in independent laboratories. With
a 10:1 safety factor, a total amount of 1,600 kg (3,527
lbs) can be flown from the 4 flying points. Each flying
point has a capacity of 400 kg (882 lbs) with a 10:1
safety factor.

The safety factor is defined as the

coefficient between the

T

The use of two hoists with a load capacity as

expressed on the previous page is mandatory. It
should be kept in mind that at certain moments, the
complete load may be supported by only one of the
hoists.

he maximum number of AERO-38 units

that can be suspended from the AX-AERO48 flying
grid is 20 (with 10:1 safety factor). T

The

maximum limits established by the manufacturer
should never be exceeded.

This is why the load capacity of the individual

hoist must be superior to the weight of the array
column.

NOTE: The rigging systems of the AERO-38 and the
AERO-48 are compatible. Some accessories (AX-
AERO38, AX-AERO48) can be used by both systems.

he maximum

number of AERO-182 units that can be suspended
from the AX-AERO48 flying grid is 16 (10:1).

Aero-38

Manual del usuario/ User´s manual

48

4 x 400Kg (10:1)

3.1 AERO-38A

3. SELF-POWERED SYSTEMS

The Aero-38A is a three way, class D, self

powered system.

Nominal amplifier power (RMS) per way:

LF:1000W MF: 500W HF:500W

Amplifier panel description:

A)

: A

B)

:

C)

:

E)

.

F1)

:

F2)

:

6

(at 230V)

G)

:

1=GND (ground)
2=(+) Non inverted input
3=(-) Inverted input

H)

:

LIMIT

SIGNAL

ON

FUSE

AC INPUT

AC OUTPUT

INPUT

LOOP THRU

D)

: Indicates that the amplifier

is under protection mode because damage risk due to
short circuit or extreme working temperature.

PROTECTION

mplifier limiter indicator lights.

When lit, the level of the signal source should be
reduced.

Signal presence indicator at the

amplifiers' inputs.

Indicator light for each amplifier

channel.

With PowerCon NAC 3 FCA

connector. Only when the connector is inserted and
rotated (clicked) into place will the AC turn on. The
connector can be used as a switch, rotating the
connector to or from the locked position will turn the
unit on or off, respectively. Mute the signal feeding the

before turning the unit on or off.

With (white) PowerCon

NAC 3 DFCB connector. This is used as an AC loop
thru so that up to boxes

can be power from

a single AC line.

Balanced signal XLR. Pin

assignments as follows :

Used for paralleling several

units, which will share the same input. The output can
also be used to provide signal for an outboard power
amplifier.

INPUT

Rear panel of the AERO-38A amplifier.

F2-PowerCon NAC 3DFCB

HF

G-Input XLR

E-Fuse

H-Output XLR

F1-PowerCon NAC 3FCA

SIGNAL

MF

LF

ON

PRO

TECTION

D

A A

A

B

ZOOM

H G

F1

E

F2

C