Diagnostic and ip configurator error messages, The cable is not plugged into port 1, The cable was not connected to the correct ports – Comtrol RocketPort Serial Hub Si 8-Port User Manual
Page 7: Hardware in one of the ports is failing, Connecting devices, Building an ethernet crossover cable, Db9 connector pinouts, Building null-modem cables, Build cables or loopback plug, Building an ethernet crossover cabl

Diagnostic and IP Configurator Error Messages
7 of 9
Diagnostic and IP Configurator
Error Messages
This table lists some error messages and possible
solutions.
Connecting Devices
Use the following discussion to connect asynchronous
devices to the RocketPort Serial Hub Si ports.
Note: Make sure that you have configured the ports
using the driver for the correct communications
mode before connecting any devices. The default
mode is RS-232. There is a remote possibility
that connecting a peripheral configured for the
wrong mode could damage the peripheral.
1.
Connect your devices to Ports 1 through 4 or 8
(depending on the model), for each RocketPort
Serial Hub Si using the appropriate cable or you
can build your own cables using the
discussions.
Note: Use the hardware manufacturer’s installation
documentation if you need help with connector
pinouts or cabling for the peripheral device.
2.
Install or reconfigure the driver using the
documentation or the driver readme
file.
Building an Ethernet Crossover Cable
If you are connecting from the
10Base-T connector on the
RocketPort Serial Hub Si
directly to the NIC card in the
server, you need a crossover
cable. Use the following
information to build or
purchase a cable.
DB9 Connector Pinouts
Use the following pinout
information for the DB9 serial port
connectors on the RocketPort Serial
Hub Si.
Building Null-Modem Cables
Use the following figure if you need to build a null-
modem cable. A null-modem cable is required to use
the bootable diagnostic, the IP Configurator utility, and
for connecting DTE devices.
Note: You may want to purchase or build a straight-
through cable and purchase a null-modem
adapter.
Error Message
Possible Causes
ERROR
DEV_NO_REPLY
1. The COM port selected in the
utility did not match the
physical COM port on the PC.
2. The cable between Port 1 on
the RocketPort Serial Hub Si
and the PC COM port is
incorrect.
3. The cable is not plugged into
Port 1.
4. The RocketPort Serial Hub Si
power was not turned off and
then on before running the
utility.
5. Port 1 is failing and the utility
can not communicate. The Port
1 LED is also lit to indicate a
hardware failure.
RS-485 ERROR
(Diagnostic)
1. The loopback cable between the
two ports is incorrect.
2. The cable was not connected to
the correct ports.
3. Hardware in one of the ports is
failing.
There were errors
during testing.
A key other than Y was entered
during the LED testing sequence
in the Diagnostic.
Caution
Pin
Connects to
Pin
1
3
2
6
3
1
6
2
Pin
RS-232
RS-422
RS-485
1
CD
Not used Not used
2
RxD
RxD-
Not used
3
TxD
TxD-
TRX-
4
DTR
Not used Not used
5
GND
Not used Not used
6
DSR
Not used Not used
7
RTS
TxD+
TRX+
8
CTS
RxD+
Not used
9
Not used Not used Not used
Pin 1
Pin 6
Receptacle
Pin 1
Pin 1
Pin 5
Pin 6
Pin 9
DB9 Male
RP
S
H
-Si
C
o
nnec
tor
TxD
RxD
RTS
CTS
DSR
GND
DCD
DTR
Signal
RxD
TxD
CTS
RTS
DTR
GND
DCD
DSR
Signal
DB9
2
3
8
7
4
5
1
6
Pins
DB25
3
2
4
7
8
6
Pins
Remot
e and R
P
S
H
-Si
DB9
3
2
7
8
6
5
1
4
Pins
20
5
Pin 9 is not connected.
Fe
m
a
le
C
o
nnec
tors
Null-Modem Cables