Tracking, Field tracking, Playback adjustment procedure – Toshiba KV-5124A User Manual
Page 17: Playback of alarm recordings
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Playback Adjustment Procedure
Carefully read the following descriptions to obtain optimum performance.
---------------TRACKING —
TRACKING
Noise appears in the picture during 2 hour playback*
• Adjust TRACKING to get a clearer picture*
FIELD TRACKING
• Adjust FIELD TRACKING to get a clearer picture when
noise appears on the screen in FIELD mode*
Note: Noise appears when a tape recorded in 2-hour
mode is played back.
In the case of 12 or 24 hour modes, noise cannot be elimi
nated by adjusting "TRACKING'
h
"FIELD TRACKING".
TRACKING
field
TRACKING
Playback of Alarm Recordings
This VCR is designed for quick review of the contents of the alarm recordings, Carefully read the following descriptions, and
become familiar with each operation.
Selection
Operation
Function
To play back a tape immediately after
aiarm recording or repeatedly play
back a certain segment of a tape.
Clear the counter to "0000" by
pressing the counter reset button at
the point on the tape which you want
to check.
Press the
COUNT. MEMORY
button.
The counter memory lamp on the
mode display will light. In this
condition, fast-forward or rewind the
tape.
The tape will automatically stop at
around "0000".
To Quickly review the tape recorded in
alarm record mode.
Press the
COUNT. MEMORY
button to
turn on the alarm memory lamp. In
this condition, fast-forward or rewind
the tape.
Still field mode will automaticaily start
at the point of the tape where the
alarm signal is recorded. Press the
PAUSE
button or
PLAY
button to start
replay.
To quickly find alarm recording date
{weekdays)
Press the
ALARM RECALL
button in
stop mode.
Alarm information on AL1 to ALB
(year, month, date, day of the week,
hour, minute, second) will automatically
appear in sequence on TV display,
starting with latest one (AL1) at 5
seconds intervals. After ALB is
displayed, this function is released.
To check the number of alarm
recordings
Press the
COUNT,
butters to show the
alarm counter on the display panel,
The number of alarm recordings will
appear up to "99".
16