beautypg.com

Lp tank exchange, Lp tank leak test, Connecting regulator to the lp tank – Kenmore 415.1613911 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

LP Tank Exchange

• Many retailers that sell grills offer you the option of

replacing your empty LP tank through an exchange service.

Use only those reputable exchange companies that inspect,

precision fill, test and certify their tanks. Exchange your

tank only for an OPD safety feature-equipped tank as

described in the "LP Tank" section of this manual.

• Always keep new and exchanged LP tanks in upright

position during use, transit or storage.

• Leak test new and exchanged LP tanks BEFORE

connecting to grill.

• Place dust cap on cylinder valve outlet whenever the

cylinder is not in use. Only install the type of dust cap on

the cylinder valve outlet that is provided with the cylinder

valve. Other types of caps or plugs may result in leakage

of propane.

LP Tank Leak Test

For your safety

• Leak test must be repeated each time LP tank is exchanged

or refilled.

• Do not smoke during leak test.

• Do not use an open flame to check for gas leaks.

• Grill must be leak tested outdoors in a well-ventilated area,

away from ignition sources such as gas fired or electrical

appliances. During leak test, keep grill away from open

flames or sparks.

• Use a clean paintbrush and a 50/50 mild soap and water

solution. Brush soapy solution onto areas indicated by

arrows in figure below. Leaks are indicated by growing

bubbles.

If “growing” bubbles appear do not use or move the LP tank.

Contact an LP gas supplier or your fire department!

A Do not use household cleaning agents. Damage to gas

valve/hose/regulator components can result.

Connecting Regulator To The LP Tank

1. LP tank must be properly secured onto grill. (Refer to

assembly section.)

2. Turn all control knobs to the OFF position.

3. Turn LP tank OFF by turning OPD hand wheel clockwise to

a full stop.

4. Remove the protective cap from LP tank valve. Always use

cap and strap supplied with valve.

Do not insert a POL transport plug

(plastic part with external threads)
into the Type 1 tank valve outlet.
It will defeat the Safety Relief

Valve feature.