Disconnecting a liquid propane gas (lp gas) – Kenmore ELITE 141.16681 User Manual
Page 13
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Connecting A Liquid Propane Gas (LP gas)
Tank To Your Grill
1. Remove the Puil-out Grease DrainingTray with the
Heat Shield from Griii.
Figure 7a (LP gas model only)
2. Locate hose and regulator assembly packed for
Shi pping purposes on front underside of grill head.
Remove fastening band. Push assembly to back of
grill and pull down to connect to tank valve. Before
connecting, check valve and assembly threads to
be sure they match. (Type 1 connection per ANSI
Z21.58b-2002) See Figure 7b.
3. inspect the valve connection port of the regulator
assembly. Look for damage or debris. Remove any
debris. Inspect hose for damage. Never use
damaged or plugged equipment.
4. Pull out the LPG Tank Pull-out Tray. Place a
20 lb tank with foot ring into the hole in the
tray. See Figure 7a. Make sure the tank
valve is in the OFF positon.
5. Align the tank so the Tank Valve faces the rear
right corner of cabinet. Use the 5/16"x89mm Wing
Bolt to secure gas tank from rear of tray.
See Figure 7a.
6. Check the tank valve to ensure it has proper
external mating threads to fit the hose &
regulator assembly provided (Type 1 connec
tion per ANSI Z21.58b-2002). See Figure 7b.
7. Make sure all Burner knobs are in the OFF
position.
8. Connect the hose and regulator assembly to the
tank valve (See Figure 7b) Hand tighten Quick
Coupling Nut clockwise to a full stop. DO NOT use
a wrench to tighten because it could damage the
Quick Coupling Nut and result in a hazardous
condition.
9. Open the tank valve fully (counterclockwise). Use a
soapy water solution to check all connections for
leaks before attempting to light your grill. See
"Checking for LP Gas Leaks" on page 15. If a leak
is found, turn the tank valve off and do not use your
grill until the leak is repaired.
Disconnecting A Liquid Propane Gas (LP gas)
Tank From Your Griii
1. Turn the Burner Knobs and LP gas tank valve
to the full OFF position. (Turn clockwise to
close.)
2. Detach the hose and regulator assembly from
the LP gas tank valve by turning the Quick
Coupling Nut counterclockwise. See Figure 7b.
CAUTION: When the appliance is not in use, the
gas must be turned off at the supply tank.
Figure 7b (LP gas model only)
NUT
SIDE BURNER.
13