beautypg.com

Light bulb changing, Agitator servicing, Warning – Kenmore POWER-MATE 116.24614 User Manual

Page 18: Electrical shock or personal injury hazard, To check agitator assembly, To replace agitator assembly, Light bulb changing agitator servicing

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

LIGHT BULB CHANGING

1. Remove Power-Male cover as shown in

BELT CHANGING AND AGITATOR CLEAN­
ING section.

2. Push in and turn
bulb counterclock­

wise, then pull out

to remove.

3. Push in and turn
bulb clockwise, to
replace. Bulb must
not be higher than
15Wa1ts(130Vo!ts).

4. Reinstall Power-Mate® cover as shown in
BELT CHANGING AND AGITATOR CLEAN­

ING section.

NOTE: See PARTS AND FEATURES for
bulb number.

AGITATOR SERVICING

WARNING

Electrical Shock Or Personal Injury
Hazard

Disconnect electrical supply before

servicing or cleaning the unit.

Failure to do so could result in elec<

trical shock or personal injury from
cleaner suddenly starting.

TO CHECK AGITATOR
ASSEMBLY

When brushes
are worn to the
level of the base
support bars,
replace the
agitator
assembly.

TO REPLACE AGITATOR
ASSEMBLY

1. Remove Power-Mate® cover, belt and
agitator assembly. See “To Remove Beit”
in BELT CHANGING AND AGITATOR
CLEANING.

2. Replace Agitator

3. Replace belt, agitator assembly, Power-
Mate*cover, light bulb and light cover.
See “To replace belt” in BELT CHANGING
AND AGITATOR CLEANING.

18