Customer Responsibilities
Thank You
for purchasing a Sears water heater. Properly
installed and maintained, it should give you years of trouble free ser
vice. if you should decide that you want the new water heater profes
sionally installed by Sears call the local Sears Service Center or any
Sears store. They will arrange for prompt, quality installation by Sears
authorized contractors.
Abbreviations Found In This Instruction Manual
CSA - Canadian Standards Association
ANSI' American National Standards Institute
NFPA - National Fire Protection Association
A WARNING
This gas-fired water heater is design certified by CSA
INTERNATIONAL
under
American
National
Standard/CSA Standard for Gas Water Heaters ANS
Z21.10.1 * CSA 4.1 (current edition). The installation
must
conform
with
this
manual,
Local
Codes
and
with
the
current
edition
of
the
National
Fuel
Gas
Code, ANSI Z223.I.
This publication is available from your local govern
ment or public library, gas company, or by writing
NFPA, I Batterymarch Park, Quincy, MA 02269.
Read the “Safety Precautions” section, pages 2 and 3 of this
manual first and then the entire manual carefully, if you don’t
follow the safety rules, the water heater will not operate prop
erly, It could cause DEATH, SERIOUS BODILY INJURY
AND/OR PROPERTY DAMAGE.
Product Specifications
This manual contains instructions for the installation, opera
tion, and maintenance of the gas-fired water heater. It also
contains warnings through out the manual that you must read
and be aware of All warnings and all instructions are essential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages, READ
THE
ENTIRE
MANUAL
BEFORE
ATTEMPTING
TO
INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; gas company rules; and Local Codes, or in the
absence of Local Codes, with the current edition of the
National Fuel Gas code, ANSI Z223.1, also referred to as
NFPA 54. I'his publication is available from your local gov
ernment or public library or gas company or by writing
NFPA, 1 Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe instal
lation are very important in preventing death from possible
carbon monoxide poisoning and fires.
Examine the location to ensure the water heater complies with
the “Locating the New Water Heater” section in this manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation proce
dures. instructions may be obtained from your local dealer,
wholesaler, public utilities or California Office of the State
Architect, 400 P Street, Sacramento, CA 95814.
Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
MODEL NUMBER
TANK
CAPACITY
IN GALLONS
TYPE
OF
GAS
B.T.U.
RATE
RECOVERY
RATE GALS.
PER HOUR
@ 90°F RISE
MINIMUM
VENT
PIPE*
DIMENSIONS IN INCHES
DIAMETER
HEIGHT TO
JACKET TOP
153.332861
40
PROPANE
40,000
42.0
3"
18"
59'//'
153.332870HA
40
PROPANE
40,000
42.0
3"
18"
59'/"
153.332880
50
PROPANE
40,000
41.5
3"
20"
60"
153.332890HA
50
PROPANE
40,000
41.5
3"
20"
60"
153.332960
40
NATURAL
40,000
42.0
3"
18"
59/"
153.332970HA
40
NATURAL
40,000
42.0
3"
18"
59/"
153.332980
50
NATURAL
40,000
41.5
3"
20"
60"
153.332990HA
50
NATURAL
40,000
41.5
3"
20"
60"
‘ Limited usage of
2
"
vent pipe - see “Venting” on pages 17-23-