Installation Instructions (cont’d)
ALL MODELS — VENTING THROUGH WALL
OPTIONAL r VENT PIPING
2" DIA.VENT
MAX. LENGTH fFT.)
NUMBER OF 90° DEG.
ELBOWS*
50
1
45
2
40
3
35
4
30
5
25
6
' NOTE: Two 45° elbows are equivalent to one 90° elbow.
One 90° elbow equals 5 feet of equivalent vent length.
ALL MODELS (3 " VENT)
See tables for max> length.
1. Tbe total vertical and horizontal vent run cannot exceed the
maximum
length with the number of 90° elbow as specified
in the following tables. If more elbows are required, the vent
ing distance must be reduced 5 feet for every 90° elbow:
2. Minimum vent length for all models is 4 feet.
ALL MODELS — VENTING THROUGH WALL
3 " DIA.VENT
NUMBER OF 90° DEG.
MAX. LENGTH fFT.)
ELBOWS*
1 15
1
110
2
105
3
100
4
95
5
90
6
19