Installation Instructions (cont’d)
Venting
A WARNING
To
insure
proper
venting
of
this
gas*fired
water
heater, the correct vent pipe diameter must be uti
lized. Any additions of other gas appliances on vent
with this water heater will adversely affect the oper
ation of the water heater.
The combustion and ventilation air flow must not be obstructed.
A WARNING
Chemical vapor corrosion of the flue and vent sys
tem may occur if air for combustion contains certain
chemical v^ors. Spray can propellants, cleaning sol
vents,
refrigerator
and
air
conditioner
refrigerants,
swimming pool chemicals, calcium and sodium chlo
ride, waxes, bleach, and process chemicals are typi
cal compounds which are potentially corrosive.
AWARNING
The power vent water heater requires its own (sepa
rate) venting system. It cannot be connected to iui ex
isting vent pipe or chimney. It must be terminated to
the outdoors. Failure to properly install the venting sys
tem can result in asphyxiation, a fire or explosion and
can cause DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.
AWARNING
Obstructed
or
deteriorated
vent
systems
may
pre
sent a serious health risk or asphyxiation.
Horizontal runs must be securely supported
at 3'A
foot intervals
and vertical runs supported at 5 foot intervals.
AWARNING
The
vent
pipe
from
the
water
heater
must
slope
upward 'A inch per five linear feet.
All vent gases must be completely vented to the outdoors of the
structure (dwelling).
AWARNING
Be sure vent pipe is properly connected to prevent
escape of dangerous flue gases which could cause
deadly asphyxiation.
VENTING THROUGH AN OUTSIDE WALL
ALL MODELS
3" PVC, ABS or CPVC Schedule 40 vent piping:
1. A3” PVC Schedule 40-45” vent cap with wire screen is sup
plied with the water heater.
2. A 3" PVC, ABS or CPVC Schedule 40-90° street ell; used to
connect the vent pipe to the water heater when the vent pipe
is to be turned horizontally directly off the blower (supplied
locally).
3. 3" PVC, ABS or CPVC Schedule 40 pipe (must be supplied
locally).
3" PVC, ABS OR. CPVC
3" PVC, ABS OR CPVC
SCHEDULE 40 PIPE
VENT CAP
WITH
SCREEN
• The water heater requires its own (separate) venting system.
• 3” PVC, ABS or CPVC Schedule 40 piping and fittings are
acceptable materials for the vent system on all models.
• It cannot be connected to existing vent piping or chimney.
• It must terminate horizontally to the outdoors.
17