Installation instructions (cont’d), Gas piping (cont’d), A warning – Kenmore THE ECONOMIZER 153.33298 User Manual
Page 24: L. p)] gases, Sediment trap
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Installation Instructions (cont’d)
Gas Piping (cont’d)
A WARNING
The appliance and its individual shutoff valve must
be disconnected from the gas supply piping sys
tem during any pressure testing of the gas system
at test pressures in excess of 1/2 pound per square
inch {3.5kPa).
The appliance must be isolated from the gas sup
ply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply
piping
system
at
test
pressures
equal
or
less than 1/2 pound per square inch (3.5kPa).
Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown.
GAS PIPING WITH
FLEXIBLE CONNECTOR
GAS SUr>PLY PIPING
MANUAL
SHUTOFF,
VALVE
A WARNING
Use pipe joint compound or teflon tape marked as
being resistant to the action of petroleum [Propane
(L. P)] gases-
SEDIMENT TRAP
A sediment trap shall be installed as close to the inlet of the
water heater as practical at the time of water heater installation.
The sediment trap shall be either a tee fitting with a capped nip
ple in the bottom outlet or other device recognized as an effec
tive sediment trap. If a tee fitting is used) it shall be installed in
conformance with one of the methods of installation shown.
GROUND JOINT
UNION
(OPTIONAL)
FLEXIBLE GAS CONNECTOR
LABELED AS COMPLYING
WITH ANSI STANDARDS
A
si
S
ud
T
DRIP LEG
(SEDIMENT
1 —0 o 5 У Т o'lsr i
3" MIN.
1
TRAP)
; CrojN ;
1
w
CAP
GAS
CONTROL
VALVE
A WARNING
Contaminants in the gas lines may cause improper
operation of the gas control valve that may result in
fire or explosion. Before attaching the gas line be
sure that all gas pipe is clean on the inside. To trap
any dirt or foreign material in the gas supply line, a
drip leg (sometimes called a sediment trap) must be
incorporated
in
the
piping.
The
drip
leg
must
be
readily accessible. Install in accordance with the "Gas
Piping” section. Refer to the current edition of the
National Fuel Gas Code, ANSI Z223.I, ^so referred
to as NFPA 54.
GAS PIPING WITH ALL BLACK IRON PIPE
TO GAS CONTROL
GAS SUPPLY PIPING
MANUAL
SHUTOFFj
VALVE
GAS
CONTROL
VALVE
24