Troubleshooting, Err 03 – Kenmore 625.34846 User Manual
Page 20
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
SECTION 5
SERVICER’S TECH. INFORMATION
5A.
TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The face plate computer has a self-diagnostic
function for the electrical system (except inpu
power and water meter). The
computer monitors the electron
ic components and circuits for
Err 03
correct operation. If a malfunction occurs, an
error code appears in the face plate display.
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all
face plate buttons are inoperable except the
SELECT button. The SELECT button remains
operational so the service p>erson can make the
MANUAL
INITIATE
ELECTRONIC
DIAGNOS
TICS to further isolate the defect, and check the
water meter.
CODE
POSSIBLE DEFECT
MOST LIKELY ^ ^ LESS LIKELY
Err 01
motor inop. / wiring harness or connection to switch / position switch / face plate
Err 02
fàce plate
Err 03
motor inop. / fóce plate .
Err 04
fóce píate / position switch
Err 05
faceplate
PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE:
1. Unplug transformer 2. Correct defect
3. Plug-in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL
INITIATED
ELECTRONICS
DIAG
NOSTICS
1.
To enter diagnostics, press and hold the
SELECT button until (000 —) shows in the
display.
MOTOR
TURBINE SWftCHCS
------1
WATER METER (A)
SWITCH (B)
A. The first 3 digits indicate water meter opera
tion as follows:
000 (steady) = soft water not in use...no
flow through the meter.
— OPEN A NEARBY SOFT WATER FAUCET-
000 to 199 (continual) = repeats display for
each gallon of water passing through the me
ter.
If you don’t get a reading in the display, with
faucet open, pull the sensor h'om the valve
outlet port Pass a small magnet back and
forth in front of the sensor. You should get a
reading in the display. If you get a reading, un
hook the in and out plumbing and <^e(^ the
turbine for binding.
POSITION
SWITCH
SENSOR
HOUSING
TURBINE
TURBINE
SUPPORT AND
SHAFT
VALVE
OUTLET
B. The letter (P) and dash(es) indicate POSI
TION switch operation. The letter appearing
means the switch is closed; the dash means
the switch is open.
Use
the
ON/OFF-HOLD
(Recharge
Now)
button to manually advance the valve into
each cycle and check correct switch opera
tion.
20