3C. KEEP THE SOFTENER FROM FREEZING
If the softener is installed where it could freeze
(summer cabin, lake home, etc.), you must drain
all water from it to stop possible freeze damage.
To drain the softener —
1.
Close the shut-off valve on the house main
water pipe, near the water meter or pressure
tank.
2.
Open a faucet in the soft water pipes to vent
pressure in the softener.
3.
Looking at FIG. 12 on page 18, move ttie
stem in a single bypass valve to bypass.
Close the inlet and outlet valve in a 3-vaive
bypass system, and open the bypass valve. If
you want water in the house pipes again,
reopen the shut-off valve on the main water
pipe.
4.
Unplug the transformer at the wall outlet.
Remove the salt hole cover and the main
cover. Take off both drain hoses.
5.
Carefully remove the large holding clips at
the softener inlet and outlet (see Key No. 61,
on page 30). Separate the softener from the
adaptors or bypass valve.
6.
Remove the brinewell cover and disconnect
the brine valve tubing at the nozzle and
venturi assembly (see page 23). Lift the brine
valve out of the brinewell. Tip the brine valve
upside down to drain out water.
FIG. 11
DRAIN WATER FROM THE
SOFTENER
7,
Looking at FIG. 11, lay a piece of 2 inch thick
board near the floor drain. Move the softener
close to the drain. SLOWLY and CAREFUL
LY tip it over until the rim rests on the wood
block with the inlet and outlet over the drain.
DO
NOT
ALLOW
THE
SOFTENER'S
WEIGHT TO REST ON THE INLET AND
OUTLET FITTINGS OR THEY WILL BREAK.
8
.
Tip the bottom of the softener up a few inches
and hold until all water has drained. Leave
the softener laying like this until you are ready
to use it. Plug the inlet and outlet with rags to
keep dirt, bugs, etc. out.