Eteotricai Connection
Power Supply Cord
Direct Wile
ikWARNING
AWARNING
M
M,
Fire Hazard
Fire Hazard
Use a new UL approved 30 amp power
Use 10 gauge solid copper wire.
supply cord.
Use a UL approved strain relief.
Use a UL approved strain relief.
Disconnect power before making electrical
Disconnect power before making electrical
connections.
connections.
Connect neutral wire (white or center wire) to
Connect neutral wire (white or center wire) to
center terminal (silver).
center terminal (silver).
Ground wire (green or bare wire) must be
Ground wire (green or bare wire) must be
connected to green ground connector.
connected to green ground connector.
Connect remaining 2 supply wires to remaining
Connect remaining 2 supply wires to remaining
2 terminals (gold).
2 terminals (gold).
Securely tighten all electrical connections.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
Failure to do so can result in death, fire, or
electrical shock.
electrical shock.
1. Disconnect power.
2, Remove the hold-down screw and temninal block cover.
3. Assemble a % in. (1.9 cm) UL approved strain relief (UL
marking on strain relief) into the hole below the terminal block
opening. Tighten strain reiief screws just enough to hold the
two clamp sections together. Put power supply cord through
the strain relief. TTie strain reiief should have a tight fit with the
dryer cabinet and be in a horizontai position.
4. Now complete Installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wlre Is not available)
7. Terminal block cover and hold down screw
2. External ground connector
3. Neutral grounding wire (green/yellow)