beautypg.com

Wire connection; direct wire, Wire connection: pow®- ^pply cord – Kenmore 8519319A User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

4-wire connection; Direct wire

IMPORTANT: A 4-wire connection is required for mobile homes

and where local codes do not permit the use of 3-wire
connections.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer

can be moved if needed.

Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving

bare ground wire at 5 in. (12.7 cm). Cut 114 in. (3.8 cm) from 3

remaining wires. Strip insuiation back 1 in. (2.5 cm). Shape ends
of wires into a hook shape.

When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example

below.

1

.

2

,

3.

Remove center terminal block screw.

Remove appliance ground wire (green with yellow stripes)

from external ground connector screw. Fasten it under center,
silver colored terminal block screw.

Connect ground wire (green or bare) of power supply cable to
external ground conductor screw. Tighten screw.

7. External ground connector

2. Green or bare copper wire of power supply cord
3. %in. (1.9 cm) UL-iisted strain relief
4. Center silver-colored terminal block screw
5. Neutral grounding wire (green/yeliow)

6

. Neutral wire (white or center wire)

4.

5.

Place the hooked end of the neutral wire (white wire) of power
supply cable under the center screw of terminal block (hook

facing right). Squeeze hooked end together. Tighten screw.

Place the hooked ends of the other power supply cable wires
under the outer temninal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.

6. Tighten strain relief screws.

7. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

3-wire connection: Pow®- ^pply cord

Use where local codes permit connecting cabinet-ground
conductor to neutral wire.

7. 3-wire receptacle (NEMA type 10-30R)

2. 3-wire plug
3. Neutral prong
4. Spade terminals with up turned ends
5. %in. (1.9 cm) UL approved strain relief

6

. Ring terminals

7. Neutral (white or center wire)

1. Loosen or remove center terminal block screw.

2. Connect neutral wire (white or center wire) of power supply

cord to the center, silver colored terminal screw of the

terminal block. Tighten screw.

3.

4.

5.

1. External ground connector

2. Neutral grounding wire (green/yeliow)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5.

¥4

in. (1.9 cm) UL-iisted strain relief

Connect the other wires to outer terminal block screws.

Tighten screws.

Tighten strain relief screws.

Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.

10