Installation, Instructions, Parts supplied – Kenmore 8519319A User Manual
Page 5: Parts needed, You will need, Installation instructions, Awarning, Location reciuiremerits
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
INSTALLATION
INSTRUCTIONS
Check that you have everything necessary for correct installation.
Proper installation is your responsibility.
Flat-blade screwdriver
Adjustable wrench that
opens to 1 in. {2.54 cm)
or hex-head socket
wrench (for adjusting
dryer feet)
Level
Wire stripper (direct wire
installations)
#2 Phillips screwdriver
Safety glasses
Duct tape
Caulking gun and
compound (for installing
new exhaust vent)
Gloves
Tin snips (new vent
installations)
V4 in. nut driver or socket
wrench
Parts supplied
Remove parts package from dryer drum. Check that all parts are
included.
4 Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a
pedestal.
Parts needed
Check local codes. Check existing electrical supply and venting.
See “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
■ For close-clearance installations between 31.5 in. (80.01 cm)
and 37 in. (93.98 cm), see “Plan Vent System” section for
venting requirements.
•*: 37"
►
(S
3
.
9
B cm)
Mobile home installations require meta! exhaust system hardware
available for purchase from your local Sears store or Sears
Service Center. For further information, please call
1-800-4-MY-HOME® (1 -800-469-4663).
Are you placing the dryer on a pedestal? You can purchase a
pedestal separately for this dryer. TTiis pedestal will add about
14 in. (35.56 cm) to the height of your unit for a tota! height of
approximately 52 in. (132.08 cm).
The pedestal is available in three colors
White - Part Number 42842
Biscuit - Part Number 42844
Graphite - Part Number 42846
To order, call your local Sears store. For further information,
please call 1-800-4-MY-HOME® (1-800-469-4663).
Location Reciuiremerits
AWARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the
floor for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will need
■ A location that allows for proper exhaust installation. See
“Venting Requirements.”
■ A separate 30 amp circuit.
■ A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See “Electrical Requirements.”
■ A sturdy floor to support the total dryer weight of 200 lbs
(90.7 kg). The combined weight of a companion appliance
should also be considered.
■ A level floor with a maximum slope of 1 in. (2.5 cm) under
entire dryer. (If slope is greater than 1 In. [2.5 cm], install
Extended Dryer Feet Kit, Part No. 279810.) Clothes may not
tumble properly and automatic sensor cycles may not
operate correctly if dryer is not level.