9732 Pflumm Road Lenexa, Kansas 66215 Phone: 913-831-0740 Fax: 913-831-9271
www.camcorpinc.com
, -)
7
. +8
3 . 9
)1 .
)- .,
2
3*(
Check alignment of the drive sprockets and tension of the chain.
Make sure that the chain is properly lubricated.
Check that the airlock feed and discharge devices are free of foreign
material.
Verify that the electrical connections have been properly attached/installed.
Replace the chain guard and make sure that all other safety devices are in
place.
Bump the motor to check for:
Freedom of rotation
Proper rotor rotation
Start unit and operate for fifteen minutes with no load, checking for hot
spots, noise and other indications of interference. Allow gear reducer to
cool to room temperature and recheck oil level. Add oil if necessary being
careful not to overfill.
Start unit and apply load. Observe operation for the first hour.
Check all connections for air leaks.
Check current draw of the motor and verify that it does not exceed its full
load rating. See motor nameplate.