8
4.1. Design with explosion
protection
DANGER!
Danger of explosion!
Improper use in hazardous explosive areas will result in
danger of explosion.
english
9
5. GENERAL INFORMATION
5.1. Contact address
Germany
Bürkert Fluid Control Systems
Sales Center
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: [email protected]
International
Contact addresses can be found on the final pages of the
printed operating instructions.
And also on the internet at:
www.burkert.com
5.2. Information on the Internet
The operating instructions and data sheets for Type 0290
can be found on the Internet at:
www.burkert.com
Documentation Type
0290
english
10
6. TECHNICAL DATA
6.1. Operating Conditions
Ambient temperature:
max. +55 °C
Permitted medium temperature depending on seal
material and coil model:
Seal material
Model with high
power or rectifier
AC/DC*
Model without
electronics
50 Hz, 60 Hz*
NBR
-10 ... +80 °C
-10 ... +80 °C
FKM
0 ... +90 °C
0 ... +120 °C
EPDM
-30 ... +90 °C
-30 ... +120 °C
* Rating plate information
Permitted media depending on seal material:
Seal material
Permitted media
NBR
Neutral media, compressed air, water,
hydraulic oil
FKM
Per-solutions, hot oils
EPDM
Oil and grease-free media e.g. hot water
Protection class: IP65 in accordance with device socket
english
11
6.2. Conformity
In accordance with the EC Declaration of conformity, Type
0290 is compliant with the EC Directives.
6.3. Standards
The conformity with EC guidelines is guaranteed in accor-
dance with standards:
EN 60204-1, EN61010-1, EN60730-1, EN 60730-2-8
6.4. Mechanical Data
Dimensions:
see data sheet
Body material:
Brass, Stainless steel (1.4581),
Gray cast iron
Sealing material:
NBR, FKM, EPDM
6.5. Fluidic Data
Circuit functions
A
(NC)
2/2-way valve,
direct-acting, normal
output A unloaded
Pressure range:
according to the design (see rating
plate)
english
Type 0290