D-1.4 Value Byte
Value Byte (VB)
Name
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
VB
Value
Value: Please refer to "Table - Host Request List" and "Table - Command Value List".
Table – Command Value List
Value
Description
Input
The input that will be connected. (Port 1 = 1, Port 2 = 2… Port n = n)
0: Disconnect
Memory
Select Memory Location
0 : Current Status (Can‘t be stored)
Enable
1: Enable Status (example: Mute, Plug)
0: Disable Status (example: Unmute, Unplug)
Level
Level Range (0 – 100)
0x81: Increase a step
0x82: Decrease a step
Delay
Audio delay time is 16-bit data. (Unit: 5 ms or 10 ms)
Delay1 - The audio delay time low byte. (Bit0 – Bit7)
Delay2 - The audio delay time high byte. (Bit8 – Bit15)
The audio delay time unit decided by the DTUF flag of the extend information.
The maximum Delay decided by the DTMAX flag of the extended information.
EDID
EDID Type
0: Fixed (Device default EDID)
1: Output 1 (Copy the EDID from the output 1)
-
Don’t care