Antari X-510 PRO User Manual
Page 6
6
Hanging Bracket
The unit may be installed at floor level or suspended overhead via the hanging bracket. If the unit is to
be mounted using the bracket, it is important that the fog does not shoot directly at any one's face.
Whatever installation method you choose, do not allow the unit to have more than a 15° angle of
inclination.
If you experience low output, pump noise or no output at all, unplug immediately. Check fluid level, the
external fuse, control module connection, and power from the wall. If all of the above appears to be
O.K., plug the unit in again. If fog does not come out after holding the control module button MANUAL
down for 30 seconds, check the hose attached to the tank to make sure there is fluid going
through the hose. If you are unable to determine the cause of the problem, do not simply continue
pushing the control module button, as this may damage the unit. Return the machine to your ANTARI
dealer.
Menu Settings With The Button FUNCTION
Setting time intervals for timer operation
Press the button
FUNCTION
until the display indicates「Interval Set」. Use the buttons
UP and
DOWN to adjust the intervals between the individual fog outputs in timer
mode within the range of 1 and 200 seconds.
Important
Always monitor tank fluid level when you are fogging. Running a fog machine with no
fluid can permanently damage the unit.
!