INSTRUCTIONS – AERCO HELITHERM STEAM GENERATOR MODEL SS1B-PLUS

SG-101-9

OP10. To SHUT DOWN the system:

a. Close all stop valves in the Primary

Steam inlet and Condensate outlet
lines.

b. In this order, close any stop valves

in:

(1) the Secondary Steam outlet line,

(2) the Cold Water inlet line.

OP11. For DRAINING THE GENERATOR, see

the instructions included under
ROUTINE MAINTENANCE.

OP12. To START UP again, with the shell filled

per step OP1 above, open the stop
valves in the following order:

a. stop valve in the Cold Water inlet

line,

b. stop valve in the Secondary Steam

outlet 1ine, and

c. stop valves in the Primary Steam

inlet and Condensate outlet lines.

OP13. After each startup, check the pressure

control, If necessary, make adjustments
per steps OP4 through OP8 above.

Figure SG-101-4. Over-Pressure Limit System Wiring Diagram