beautypg.com

A&D Weighing SJ-30KWP User Manual

Page 25

background image

23

Item

Parameter

Description

0

Five-level (Result LED blinks.)

1

Five-level (Result LED lights.)

2

Three-level (Result LED blinks.)

3

Three-level (Result LED lights.)

4

Seven-level (Result LED blinks.)

Comparator mode

Cp-l

5

Seven-level (Result LED lights.)

Sets comparator
mode

0

Comparator disabled

1

Compares all data

2

Compares all stable data

3

Compares all data of

≥ +5d or ≤ -5d

4

Compares stable data of

≥ +5d or ≤ -5d

5

Compares data of

≥ +5d

Comparison
conditions

Cp

6

Compares stable data of

≥ +5d

Sets comparison
conditions

d = minimum display

in kg

0

Dark

1

2

3

Comparator
LED brightness

Cp-i

4 Bright

Adjusts LED
brightness of
comparison result

0

Normal comparison

Normal/Negative
comparison

Cp-p

1

Negative comparison for take-away

check weighing

Refer to
“9. AUTO-TARE”

0

Auto-tare function disabled

Auto-tare
function

at

1

Auto-tare function enabled

Refer to
“9. AUTO-TARE”

0

Immediately after OK and stable

1

0.5 second after OK and stable

2

1.0 second after OK and stable

3

1.5 seconds after OK and stable

4

2.0 seconds after OK and stable

5

2.5 seconds after OK and stable

6

3.0 seconds after OK and stable

7

4.0 seconds after OK and stable

8

5.0 seconds after OK and stable

Auto-tare timing

at-t

9

10 seconds after OK and stable

Timing to tare
automatically after
the comparison OK
and stable weight.

0

Function disabled

Auto-tare of the
initial weight

at-f

1

Tares the initial (container) weight.

Automatic operation

Factory setting

This manual is related to the following products: