Inovonics EN4216MR User Manual
Page 9

© Inovonics, 2011 - www.inovonics.com
9
16 DMP XR500 Control Panel Wiring and Programming Information
16.1 Typical EN4216MR Receiver Connection to DMP XR500 Control Panel
EN4216MR Function
EN4216MR
Terminal
Panel Terminal
Keypad Text
Power in (12V DC)
Vs
(7) RED
n/a
Ground
GND
(10) BLK
n/a
NC (1)
Alarm 1
Com 1
(14) GND
Zone 1
(Follower)
NO (1)
(13) Z1
(user text)
NC (2)
Alarm 2
Com 2
(14) GND
Zone 2
(Follower)
NO (2)
(15) Z 2
(user text)
NC (3)
Repeater AC Loss
Com 3
(17) GND
Zone 3
(Follower)
NO (3)
(16) Z 3
RF Repeater AC
NC (4)
RF Pt Low Battery
Com 4
(17) GND
Zone 4
(Latching)
NO (4)
(18) Z 4
RF Pt Low Batt
NC (5)
RF Pt Tamper
Com 5
(20) GND
Zone 5
(Latching)
NO (5)
(19) Z 5
RF Pt Trouble
NC(6)
RF Pt Inactive
Com 6
(20) GND
Zone 6
(Follower)
NO (6)
(21) Z 6
RF Pt Inactive
Power Loss
POWER LOSS
(22) Z 7
Zone 7
(Follower)
GND
(23) GND
RF Recvr Power
Receiver Tamper
TAMP *
n/a
n/a
RF Jam
JAM
(24) Z 8
Zone 8
(Follower)
n/a
RF System Jammed
* Add the following two connections to combine receiver tamper and transmitter tamper:
1.
Connect a 2K-ohm resistor from TAMP terminal to COM 5.
2.
Connect a jumper wire from TAMP terminal to NO 5 terminal.