Specifications – Hardy Advantage HI LPRC03 Load Point User Manual
Page 18
![background image](/manuals/657651/18/background.png)
HI HLPRC03 SERIES LOAD POINT ASSEMBLY
Page 12
Specifications
Operating Specifications
•
Rated Output (F.S.)2+-0.002mv/v
•
Non-Linearity+-0.012% R.O.
•
Hysteresis<+-0.025% R.O.
•
Zero Balance<+-1.0% R.O.
•
Creep @ 5 Min.<+-0.010% R.O.
•
Temp Effect Output<+-0.0014% R.O./C (.0011
on RCHO3)
•
Temp Effect Sensitivity<+-0.0010% R.O./C
(.0005 on RCHO3)
•
Input Resistance1050 to 1200 ohms +/- 50
•
Output Resistance1000 +- 1 ohm +/- 10
•
Insulation Resistance >5000 megohms
•
Excitation 5-15VDC
•
Safe Load Limit 200% Emax
•
Ultimate Load 300% Emax
•
Safe Side Load 100% Emax
Environmental Specifications
• Operating TemperatureMinus 40
o
F to Plus176
o
F (-40
o
C to +80
o
C)
• Compensated Temperature14
o
F to 104
o
F
(Minus 10
o
C to Plus 40
o
C)
Capacity
Model #
Model #
LBS
MT
Fixed Assembly
Spare Load Sensor
66K
30
HI LPRC03-66K-45C
HI RCH03-66K
110K
50
HI LPRC03-110K-45C
HI RCH03-110K
200K
90
HI LPRBc03-200K-45C
HI RCH03-200K
TABLE 1: MODEL NUMBERS & CAPACITIES