beautypg.com

10 repairs, Repairs – FRITSCH PULVERISETTE 4 classic line User Manual

Page 47

background image

10

Repairs

DANGER!
Mains voltage!
– Before beginning with repair work, unplug the mains

plug and protect the device against being unintention-

ally switched back on.

– Indicate repair work with warning signs.
– Repair work may only be performed by specialised per-

sonnel.

– Put safety equipment back into operation after mainte-

nance work.

Fault description

Cause

Remedy

The ready status indicator

doesn't light up

No mains connection

Plug in mains plug

Main switch (8)

Switch on main switch

START button is pressed but mill

does not start up

Check if POWER SUPPLY is lit

see above

Pause time active

Wait for end of pause or press "STOP"

Safety lock was opened manually see Ä Chapter 2.6.1 ‘Opening the hood

without mains connection’ on page 14

Mill reduces speed automati-

cally

if display is blinking: Overload

Reduce load or accept automatically set rota-

tional speed

Mill stops running

Switched off due to thermal

overload of the drive

Allow device to cool down and select a lower

speed

Imbalance of machine too high

Improve mass balance, see Ä Chapter 6.6

‘Mass balance’ on page 34

Drive was blocked

Rectify malfunction in grinding chamber

Toothed belt of motor loose or

broken

Check toothed belt, replace if necessary

The hood cannot be opened

No mains connection

Plug in mains plug

Main switch (8)

Switch on main switch

Grinding stock escapes

Clamping device loose

clamp again

Seal ring is soiled or defective

Clean or replace seal ring

Runs unevenly with strong

vibrations

Bowls are imbalanced

Arrange the bowls symmetrically (equal

masses in the opposite positions)

Error code 5 blinks in the display Emergency off switch (5) pressed Unlatch the emergency off switch

Error code 6

Invalid program data

Rotational speed or grinding duration must not

be set to zero.

Repairs

- 47 -