Specifi cations

2 AA, common alkaline batteries. Operational battery life over 40 hours at

room temperature. Battery life is reduced at lower temperatures.

Dot graphic LCD display

Power, Wire, Escape/Clear (Esc), Next ( ) and four softkeys with chang-

ing fuction and label, depending on the specifi c menu in use

Unit of measure, battery level

Temperature accuracy approximately ±2° F (±1°C)

2,000 lbf/ 1,000 kgf/ 10,000 N CTM instrument:

Displayed resolution setting

Low

Med

High

lbf (pound-force)

10 lbf

5 lbf

2 lbf

kgf (kilogram-force)

5 kgf

2 kgf

1 kgf

N (Newton)

50 N

20 N

10 N

Custom units

between 101 &

200 divisions

between 201 &

500 divisions

between 501 &

1000 divisions

8,000 lbf/ 3,500 kgf/ 35,000 N CTM instrument:

Displayed resolution setting

Low

Med

High

lbf (pound-force)

50 lbf

20 lbf

10 lbf

kgf (kilogram-force)

20 kgf

10 kgf

5 kgf

N (Newton)

200 N

100 N

50 N

Custom units

between 101 &

200 divisions

between 201 &

500 divisions

between 501 &

1000 divisions

For ease of use, the display always counts by a multiple of 1, 2 or 5.

Varied wire sizes

Suitable for outdoor use

10˝ x 23˝ x 3˝ (25 cm x 59 cm x 8 cm) approximately

11 lb (5 kg) approximately

Power

Display

Operational keys

Operational annunciators

Available options

Operating environment

Dimensions

Weight

Temperature detection

Display resolution

2

5.0 Achieving Best Accuracy

The CTM is an instrument designed to give accuracy that typically exceeds
normal requirements for wire tensioning. You should have an understanding
of what factors affect tension measurement accuracy.

While it is best to have the instrument calibrated to the specifi c wire size(s)
and type(s) used, the CTM can often work adequately in other situations. If
the best tension accuracy is required, it is recommended that a calibration
be performed for that specifi c wire size and type.

What calibration choice and sheaves should I use?

Situation

Wire calibration

selection

Sheave

selection

Accuracy

Exact wire size

and type is

shown in wire list

Description of

exact match

Sheaves noted

in list

Best

Wire size is

same, but type is

not identical

Description of

same wire

diameter

Sheaves noted

for that wire size

Good

Wire size is not

the same

Closest diameter

Sheaves match-
ing the wire size
being measured

Fair

Do not use the CTM to measure tension for wires if both of the following are
true:

1. No wire calibrations are stored of the same diameter as the wire you are

looking to measure, and

2. You do not have sheaves of the same diameter.

If both of these conditions exist, contact your distributor.

Contact your distributor to improve accuracy for a specifi c wire type by
calibrating to it.

A tensiometer works by defl ecting the cable, which makes the cable path
longer than when a tensiometer is not installed. When the tensiometer is
removed, the wire tension decreases as the cable length is restored. This
effect is known as loading error. The CTM design elongates the cable by a
mere 0.08 inch (2 mm), making loading errors extremely small.

The CTM’s sheave with bearing design provides the best mechanical
performance. It is also superior at detecting tension that is being added or
removed.

5.1 Accuracy

5.2 Calibration to
Specifi c Wire Type

5.3 Loading Error

5.4 Non-repeatability

Contact your distributor for any
additional calibrations you may
need.