beautypg.com

Checkline Series-4 User Manual

Page 25

background image

Series 4 Digital Force Gauges

User’s Guide


24

12.3 Capacity, Resolution & Load Cell Deflection



12.4 Dimensions
IN [MM]



Thread

Hex

M4-012 – M4-100

#10-32 UNF

5/16 [7.94]

M4-200 – M4-500

5/16-18 UNC

11/32 [8.74]

Model

Capacity

Resolution

Load Cell

Deflection

in [mm]

lbF

ozF

kgF

gF

N

kN

mN

lbF

ozF

kgF

gF

N

kN

mN

M4-012

0.12

2

50

0.5

500

0.00005

0.001

0.02

0.0002

0.2

0.005 [0.13]

M4-025

0.25

4

100

1

1000

0.0001

0.002

0.05

0.0005

0.5

0.010 [0.25]

M4-05

0.5

8

250

2.5

2500

0.0002

0.005

0.1

0.001

1

0.010 [0.25]

M4-2

2

32

1

1000

10

0.001

0.02

0.0005

0.5

0.005

0.010 [0.25]

M4-5

5

80

2.5

2500

25

0.002

0.05

0.001

1

0.01

0.010 [0.25]

M4-10

10

160

5

5000

50

0.005

0.1

0.002

2

0.02

0.010 [0.25]

M4-20

20

320

10

10000

100

0.01

0.2

0.005

5

0.05

0.010 [0.25]

M4-50

50

800

25

25000

250

0.02

0.5

0.01

10

0.1

0.010 [0.25]

M4-100

100

1600

50

50000

500

0.05

1

0.02

20

0.2

0.010 [0.25]

M4-200

200

3200

100

1000

1

0.1

2

0.05

0.5

0.0005

0.010 [0.25]

M4-500

500

8000

250

2500

2.5

0.2

5

0.1

1

0.001

0.010 [0.25]